manualshive.com logo in svg
background image

This product should not be thrown in the garbage. 
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must 
be collected and returned to an authorized recycling facility.

Warranty

JBC’s 2 year warranty covers this equipment against 
all manufacturing defects, including the replacement 
of defective parts and labour.
Warranty does not cover product wear or misuse. 
In order for the warranty to be valid, equipment must 
be returned, postage paid, to the dealer where it was 
purchased. 

Get 1 extra year JBC warranty by registering here: 
https://www.jbctools.com/productregistration/ 
within 30 days of purchase.

40 mm

50 mm

60 mm

80 mm

100 mm

130 mm

130 mm

para manuales - color gris

200 mm

300 mm

003

105

2-

03

03

23

TIA
Analogic Thermometer

Ref.: 

TIA-A

-  Temperature range: 

20 - 500 °C / 69 - 920 °F

-  Thermocouple: 

Type E 

-  Ambient temperature correction:  Adjusted for 20 °C / 68 °F
-  Scale Unit: 

10 °C / 20 °F

-  Total weight: 

0.7 kg / 1.5 lb

Complies with CE standards.
ESD Safe.

Specifications

Содержание TIA

Страница 1: ...TIA Analogic Thermometer INSTRUCTION MANUAL ...

Страница 2: ...Packing List The following items are included Thermometer 1 unit Ref TIA A Cable 1 unit Ref 0780476 Manual 1 unit Ref 0031052 This manual corresponds to the following reference TIA A 2 ...

Страница 3: ...eading 2 Read the temperature 1 Apply solder Place the tip in the centre of the sensor This is reinforced for this purpose Wait until the temperature stabilizes For a correct temperature reading you need to apply solder to the center of the sensor wire www jbctools com 3 ...

Страница 4: ... end of the cable to the metal part of the tool stand and the other end to the cartridge and proceed according to the instructions in Operation steps 1 2 Reading the Sleep temperature Connect both ends as shown 4 ...

Страница 5: ...a reading on the thermometer 4 Take note of the deviation to correct future readings 5 Fit the STA sensor in place TIA Pattern generator Thermocouple Type E Calibration STA Sensor for TIA 1 Pull out the sensor and adjust the reading needle using a screwdriver at room temperature www jbctools com 5 ...

Страница 6: ...Changing the sensor To replace the STA sensor pull it off the base 6 ...

Страница 7: ...Notes www jbctools com 7 ...

Страница 8: ...anty does not cover product wear or misuse In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased Get 1 extra year JBC warranty by registering here https www jbctools com productregistration within 30 days of purchase para manuales color gris 0031052 030323 TIA Analogic Thermometer Ref TIA A Temperature range 20 500 C 69 920 F Thermocoupl...

Отзывы: