Maintenance and Filter Replacement
- The fume extractor unit indicates by means
of display and LED’s that the filters need to
be replaced.
- To replace the filters remove the cover by
opening the quick release levers, located
on both sides of the casing.
- If the saturation indicator remains in red
after replacing the pre-filter, it means that
the compact filter is saturated and must
also be replaced (see figure below).
- After replacing the compact filter, the
carbon filter counter must be reset (Main
Menu > Filter Set > Reset Carbon).
- The service life of the compact filter is
a maximum of 1 year after opening its
packaging.
- If the filter is changed while the fume
extractor is switched on, the fume extractor
unit automatically starts the filter detection
process and activates the aspiration for a few
seconds.
Cover
Casing
Pre-Filter
Compact Filter
Connect the filter tube to the
quick-coupling placed on the metal
sheet
The filter has a given position.
Make sure the filter ribs mate with
the corresponding slots.
Quick Release
Lever
Filter
Ribs