background image

20%

Saturation

Aspiration

ON

ON

Carbon life

80%

Fume Extractor

Ref.  FAE1-1B (100V / 120V)
 

FAE1-2B (230V)

Flexible arms Ø50

Ref. FAE070
Lenght: 1 m (39.37 in)

To be assembled on 
your workbench with
the included clamp

Flexible Hoses Ø50

Ref. FAE010 
Lenght: 1,5 m 
(59.05 in)

Connect the Fume 
Extractor to the flexible arm

Attention

Avoid awkward positions
in order to minimize 
pressure losses

2 work intakes configuration assembly (optional configuration)

Main screen

Troubleshooting

Station troubleshooting available on the product page at www.jbctools.com

Aspiration status

In this configuration aspiration at stand is not available, aspiration flow is set High. Note that in this 
configuration, suction force per intake is decreased when compared to 1 work intake configuration (see 
details on page 14). Change Work intakes parameter into 2 in order to set this configuration (see page 
7).

Ref. FAE020

To be assembled directly 
on your workbench 
(hole drilling required)

www.jbctools.com

5

Содержание FAE1

Страница 1: ...Fume Extractor Ref FAE1 B INSTRUCTION MANUAL www jbctools com ...

Страница 2: ...led Packing List The following items are included Fume Extractor 1 unit Ref FAE1 1B 100V 120V FAE1 2B 230V Unseal the filter before the first use Manual 1 unit Ref 0023483 Power cable 1 unit Ref 0009417 100V 120V 0009401 230V RJ12 direct cable 2 units Ref 0019751 RJ12 USB A adapter 1 unit Ref 0023504 USB A B cable 1 unit Ref 0021042 2 ...

Страница 3: ... intakes configuration Quick release levers for filter change Power socket Main switch Process screen USB B connection Pedal connection RJ12 station connections Filter saturation indicator Green Filter OK Yellow 20 carbon lifetime or about to saturate Red End of carbon lifetime or filter saturated www jbctools com 3 ...

Страница 4: ...B versions onwards Flexible arm Ø50 Ref FAE070 Lenght 1 m 39 37 in To be assembled on your workbench with the included clamp Ref FAE020 To be assembled directly on your workbench hole drilling required Flexible Hoses Ø50 Ref FAE010 Lenght 1 5 m 59 05 in Connect the Fume Extractor indifferently to the flexible arm or to the accessory for stand aspiration Attention Avoid awkward positions in order t...

Страница 5: ...k intakes configuration assembly optional configuration Main screen Troubleshooting Station troubleshooting available on the product page at www jbctools com Aspiration status In this configuration aspiration at stand is not available aspiration flow is set High Note that in this configuration suction force per intake is decreased when compared to 1 work intake configuration see details on page 14...

Страница 6: ... Interface Main Screen Main screen may vary according to the Work intakes and Program parameters For 1 work intake configuration the aspiration flow can be changed by keys whereas for 2 work intakes configuration the flow cannot be changed Change the aspiration Custom level and the aspiration Preset program Turning on the fume extractor Once the fume extractor is turned on the display shows a simi...

Страница 7: ...1 Program Ctm 100 2 Delay to stop 3 Pedal Back Back Total Counters Total Counters 1 Plugged hrs 100 2 Idle hrs 10 3 Work area hrs 70 4 Stand hrs 20 5 Work area cys 10 Back Back Partial Counters Partial Counters 1 Plugged hrs 100 2 Idle hrs 10 3 Work area hrs 70 4 Stand hrs 20 5 Work area cys 10 6 Reset Back Back 5 Work intakes 1 Back Back Menu Interface Main menu parameters Original PIN 0105 1 wor...

Страница 8: ...ect work area flow 80 Port Port 1 Program Ctm 100 2 Delay to stop 3 Pedal Back Back Port Port 1 Program Ctm 100 2 Delay to stop 3 Pedal Custom Custom Back Back Port Port 1 Pedal Back Back Pedal Pedal 1 Activation One touch 2 Mode Pressed Back Back Menu Interface 1 Port menu 1 work intake configuration OK 2 Port menu 2 work intakes configuration 8 ...

Страница 9: ...tive until continuous mode is disabled or the equipment is powered off By default Continuous mode is OFF Beep Enable disable the sound of the keypad By default Beep is ON PIN Enable disable PIN request when modifying parameters By default PIN is ON Change PIN Change the default security PIN code By default the PIN is 0105 Work intakes It sets how many intakes will work as workbench extractions The...

Страница 10: ...M Medium aspiration program is selected Delay to stop Stand It sets the time that a fume extractor keeps aspirating fumes at the stand once the tool is returned to it range 0 999 seconds By default Stand time is 60 seconds Pedal Activation It sets the pedal activation mode One touch Press the pedal once to activate aspiration Press again to stop aspiration Pressed Mode function must be Pressed asp...

Страница 11: ...layed on the main screen When 0 is reached the system will show pop up message STOP 1 to replace the filter Saturation It shows saturation status of HEPA carbon filter set expressed in It is also displayed on the main screen When 100 is reached the system will show pop up message STOP 2 to replace the filter Reset carbon Perform this action after replacing the HEPA carbon filter set The car bon li...

Страница 12: ...751 RJ12 cable Connect up to 4 stations directly to a fume extractor through the Soldering Station Robot port Every tool connected to a station can control the aspiration system but previously it has to be assigned to the fume extractor through the Peripherals menu of the station Each station detects a fume extractor as a FAE_a For a correct operation always update soldering stations with the late...

Страница 13: ... the equipment software Fume extractor can be updated by means of JBC Updater software If you want to update the equipment be aware there is not a station connected to RJ12 connectors If a station is connected to RJ12 connector the update process will not start Download software from https www jbctools com software html Continuous mode When continuous mode is enabled fume extractor suction is acti...

Страница 14: ...lable Power consumption 110 W 115 W 120V 50 60Hz 1 work intake 2 work intakes Work aspiration intakes 1 2 Stand aspiration intakes 1 Not available Flow per work intake 80 m3 h 47 08 cfm 60 m3 h 35 31 cfm Preset aspiration programs 3 1 Custom aspiration programs 10 Not available Power consumption 115 W 135 W 100V 50 60Hz 1 work intake 2 work intakes Work aspiration intakes 1 2 Stand aspiration inta...

Страница 15: ... must be replaced too See Filter replacement instruction on page 16 When the H13 particle filter has been replaced the carbon filter counter must be reseted Main Menu Filter set Reset carbon The duration of the compact filter is 1 year maximum after its packaging is opened If the filter is changed while the fume extractor is on the unit starts the filter detection process activating aspiration for...

Страница 16: ...der to adjust the filter airtightness Read safety guidelines to do the equipment maintenance safely Connect the filter tube to the quick coupling placed on the metal sheet The filter has a given position Make sure the filter ribs mate with the corresponding slots Maintenance Filter replacement 16 ...

Страница 17: ...riate protective mask glasses and gloves when handling dirt filter or pre filter Do not use the equipment without the filters Saturated filters can not be cleaned and reused Avoid blowing the filter or the dirty parts of the equipment if necessary it is advisable to vacuum Avoid losing particles in the filter during handling it Treat the saturated filters as waste depending on the filtered contami...

Страница 18: ...Notes 18 ...

Страница 19: ...Notes www jbctools com 19 ...

Страница 20: ...as purchased Get 1 extra year JBC warranty by registering here https www jbctools com productregistration within 30 days of purchase www jbctools com 0023483 0420 Specifications FAE1 1B 100V 50 60Hz Input power 105W Fuse 2A 120V 50 60Hz Input power 135W Fuse 2A FAE1 2B 230V 50 60Hz Input power 115W Fuse 1 25A Weight 10 5 kg 23 2 lb Dimensions 382 x 344 x 476 mm 15 x 13 5 x 18 7 in Blower type Brus...

Отзывы: