STOP 

STOP 

#

#

4

4

Cover opened or badly 
closed. Double check the 
cover.

Flow

Flow

H

M

L

Saturation 20%

Filter

Filter

Carbon life 90%

Aspiration

ON

Flow

Flow

H

M

L

Saturation 20%

Filter

Filter

Carbon life 90%

Aspiration

ON

Flow

Flow

Saturation 20%

100%

Filter

Filter

Carbon life 90%

Aspiration

ON

20%

Saturation

Aspiration

ON

ON

Carbon life

80%

If the display shows STOP#4, power off the fume extractor, remove the cover, place it back and 
secure it using the quick release levers.

Menu Interface

Main Screen

Main screen may vary according to the Work intakes and Program parameters. For 1 work intake 
configuration the aspiration flow can be changed by keys, whereas for 2 work intakes configuration 
the flow cannot be changed.

Change the aspiration 
Custom level and the 
aspiration Preset program.

Turning on the fume extractor

Once the fume extractor is turned on, the display shows a similar screen as the following one and 
the filter saturation indicator is green if the carbon lifetime is higher than 20%.

Troubleshooting

Station troubleshooting available on the product page at www.jbctools.com

1 work intake configuration

1

2 work intakes configuration

2

6

Содержание FAE1-B

Страница 1: ...Fume Extractor Ref FAE1 B INSTRUCTION MANUAL www jbctools com...

Страница 2: ...ed Packing List The following items are included Fume Extractor 1 unit Ref FAE1 1B 100V 120V FAE1 2B 230V Unseal the filter before the first use Manual 1 unit Ref 0023483 Power cable 1 unit Ref 000941...

Страница 3: ...intakes configuration Quick release levers for filter change Power socket Main switch Process screen USB B connection Pedal connection RJ12 station connections Filter saturation indicator Green Filter...

Страница 4: ...B versions onwards Flexible arm 50 Ref FAE070 Lenght 1 m 39 37 in To be assembled on your workbench with the included clamp Ref FAE020 To be assembled directly on your workbench hole drilling required...

Страница 5: ...intakes configuration assembly optional configuration Main screen Troubleshooting Station troubleshooting available on the product page at www jbctools com Aspiration status In this configuration aspi...

Страница 6: ...Interface Main Screen Main screen may vary according to the Work intakes and Program parameters For 1 work intake configuration the aspiration flow can be changed by keys whereas for 2 work intakes co...

Страница 7: ...Program Ctm 100 2 Delay to stop 3 Pedal Back Back Total Counters Total Counters 1 Plugged hrs 100 2 Idle hrs 10 3 Work area hrs 70 4 Stand hrs 20 5 Work area cys 10 Back Back Partial Counters Partial...

Страница 8: ...ct work area flow 80 Port Port 1 Program Ctm 100 2 Delay to stop 3 Pedal Back Back Port Port 1 Program Ctm 100 2 Delay to stop 3 Pedal Custom Custom Back Back Port Port 1 Pedal Back Back Pedal Pedal 1...

Страница 9: ...ive until continuous mode is disabled or the equipment is powered off By default Continuous mode is OFF Beep Enable disable the sound of the keypad By default Beep is ON PIN Enable disable PIN request...

Страница 10: ...Medium aspiration program is selected Delay to stop Stand It sets the time that a fume extractor keeps aspirating fumes at the stand once the tool is returned to it range 0 999 seconds By default Sta...

Страница 11: ...ayed on the main screen When 0 is reached the system will show pop up message STOP 1 to replace the filter Saturation It shows saturation status of HEPA carbon filter set expressed in It is also displ...

Страница 12: ...51 RJ12 cable Connect up to 4 stations directly to a fume extractor through the Soldering Station Robot port Every tool connected to a station can control the aspiration system but previously it has t...

Страница 13: ...the equipment software Fume extractor can be updated by means of JBC Updater software If you want to update the equipment be aware there is not a station connected to RJ12 connectors If a station is c...

Страница 14: ...able Power consumption 110 W 115 W 120V 50 60Hz 1 work intake 2 work intakes Work aspiration intakes 1 2 Stand aspiration intakes 1 Not available Flow per work intake 80 m3 h 47 08 cfm 60 m3 h 35 31 c...

Страница 15: ...must be replaced too See Filter replacement instruction on page 16 When the H13 particle filter has been replaced the carbon filter counter must be reseted Main Menu Filter set Reset carbon The durati...

Страница 16: ...er to adjust the filter airtightness Read safety guidelines to do the equipment maintenance safely Connect the filter tube to the quick coupling placed on the metal sheet The filter has a given positi...

Страница 17: ...iate protective mask glasses and gloves when handling dirt filter or pre filter Do not use the equipment without the filters Saturated filters can not be cleaned and reused Avoid blowing the filter or...

Страница 18: ...Notes 18...

Страница 19: ...Notes www jbctools com 19...

Страница 20: ...s purchased Get 1 extra year JBC warranty by registering here https www jbctools com productregistration within 30 days of purchase www jbctools com 0023483 0420 Specifications FAE1 1B 100V 50 60Hz In...

Отзывы: