manualshive.com logo in svg
background image

JBC  

Manager

JBC  

Updater

www.jbctools.com

· Change temperature  
  (from 90 to 450ºC)

Tool Settings:
· Select temperature levels
· Fix one temperature

Tool Settings:
· Set Sleep temperature  
· Set Sleep delay 
  (from 0 to 9 min or no Sleep)

Tool Settings:
· Set Hibernation delay  
  (from 0 to 35 min or no 
   hibernation)

8

9

USB Connector

Download the latest software from our website to improve your soldering station.

JBC Updater 

www.jbctools.com/software.html  
 
Update the station software via USB connection: 

JBC Manager

 

www.jbctools.com/manager.html 
 
Manage and monitor as many stations as your PC can handle by using the JBC Manager. You can 
export data to another PC. 

Cable   USB AB

Register Settings

Create graphs of the  
soldering process in real time 
with power and temperature 
data.

Manager Settings

Change settings for a group 
of JBC stations at the same 
time.

any JBC  

station

USB  

Hub

 

Cable    

USB AB

Operation

The JBC Exclusive Heating System

Our revolutionary technology is able to recover tip temperature extremely quickly. It means the user 
can work at a lower temperature and improve the quality of soldering. Tip temperature is further 
reduced thanks to the Sleep and Hibernation modes which increase tip life by 5.

1. Work

When the tool is lifted from the 
stand the tip will heat up to the 
selected temperature. 

2. Sleep

When the tool is in the stand, 
the temperature falls to 
180ºC / 360ºF (preset sleep 
temperature).

Tool in the stand

A c t u a l   T e m p .   1 8 0

o

C

Sleep

Tool in the stand after sleep

No heat

A c t u a l   T e m p .   2 0

o

C

Hibernation

0

c

Selected temp.  350 

o

C

P o w e r   1 0 %

350

Long time  
in the  
stand

3. Hibernation

After longer periods in the stand 
(pre-set to 30 minutes), the  
power is cut and the tool  
cools down to room temperature.

Содержание CP-D

Страница 1: ...www jbctools com Espa ol 15 English 3 Page Compact Micro Tweezers Station Ref CP D...

Страница 2: ...included CP Control Unit 1 unit Ref CP 1D 120V CP 2D 230V CP 9D 100V Brass Wool 1 unit Ref CL6210 www jbctools com Sponge 1 unit Ref S0354 Micro Tweezers 1 unit Ref PA120 A Cartrdiges 2 units Ref C12...

Страница 3: ...rocess Control Adjustable Stand Intelligent Heat Management Equipotential connection USB B connector Features Micro Tweezers Ref PA120 A Adjustable stand Cable collector Adjust the tool stand to suit...

Страница 4: ...20 When used carefully it provides a more thorough cleaning Splashguard Tip Wipe Changing cartridge Compatible cartridges CP station works with C120 cartridge range Check the model that best adapts to...

Страница 5: ...ager Settings Change settings for a group of JBC stations at the same time any JBC station USB Hub Cable USB AB Operation The JBC Exclusive Heating System Our revolutionary technology is able to recov...

Страница 6: ...eset settings 2 Station settings 3 Tool settings Before carrying out maintenance or storage always allow the equipment to cool Clean the station screen with a glass cleaner or a damp cloth Remove the...

Страница 7: ...d when not in use in order to activate the sleep mode Thesolderingtip themetalpartofthetoolandthestandmaystillbehotevenwhenthestationis turned off Handle with care including when adjusting the stand p...

Страница 8: ...CP 1 unidad Ref CP 1D 120V CP 2D 230V CP 9D 100V Brass Wool Lana de lat n 1 unidad Ref CL6210 www jbctools com Sponge Esponja 1 unidad Ref S0354 Micro Tweezers Micro pinzas 1 unidad Ref PA120 A Cartrd...

Страница 9: ...icro pinzas Ref PA120 A Soporte Ajustable Recogecable Ajuste el soporte de la herramienta para adaptarlo a su posici n de trabajo Coloque el cable en el recogedor y ajuste su posici n para evitar mole...

Страница 10: ...guard not supplied Inox Wool Lana inoxidable Ref CL6205 Un m todo alternativo a la lana de lat n Metal Brush Cepillos de metal Ref CL6220 Si se utiliza con prudencia proporciona una limpieza m s profu...

Страница 11: ...tings Menu Configure la temperatura de Sleep Retrase la entrada al modo Sleep de 0 a 9 min o no Sleep Tool Settings Menu Retrase la entrada al modo Hibernation de 0 a 35 min o no Hibernation Funcionam...

Страница 12: ...350 Exit 1 Reset settings 2 Station settings 3 Tool settings Antes de almacenar o de su mantenimiento el equipo debe estar desconectado de la fuente de alimentaci n y dejar que se enfr e Use un pa o...

Страница 13: ...e cuando no est en uso con el fin de activar el modo de Sleep El cartucho la parte met lica de la herramienta y el soporte puede estar caliente incluso cuando la estaci n est apagada Maneje con cuidad...

Страница 14: ...www jbctools com 26 27 Exploded View Despiece...

Страница 15: ...ta garant a de 2 a os cubre este equipo contra cualquier defecto de fabricaci n incluyendo la sustituci n de partes defectuosas y mano de obra La garant a no cubre el desgaste del producto por uso o m...

Отзывы: