Station Settings
Minimum Temperature
Set the minimum temperature
to work with.
Defaut min. temp. is 200 ºC
(392 ºF). This is considered to
be a proper starting point for
leaded applications.
Maximum Temperature
Set the maximum
temperature to work with.
Default max. temp is 400 °C
(750 °F). This is considered
high enough to work with
most lead-free applications.
Temperature Unit
Celsius (ºC) or Fahrenheit (ºF)
Recommendations
Parameter Description
N/a
Warnings
The station temperature
range is 90-450 ºC
(190-840 ºF). Change the
temperature limits when
working with less common
applications such as low / high
melting point soldering (HMP)
or plastics (e. g. riveting).
In most cases,
working with temperatures
over 400 °C (750 °F) can
damage the PCB and its
components. Even in short
time periods of tip contact
with the soldering joint, the
flux may not work properly
and could seriously reduce
tip life. If the solder joint
requires more power
(e.g. multilayered or high
dissipation boards), JBC
strongly recommends using
other aids like preheaters.
Be careful when using these parameters as they may reduce the tip life if not used properly.
Please follow the recommended guidelines:
Parameters
Metronome
This activates a beep sound.
Frequencies vary from 1 to 50
seconds.
Change Pin
Change the default security
The PIN must be entered every
time a parameter is changed.
Useful for setting a work rate
in repetitive jobs. The beep
lets you know the length of
time the tip must be in contact
with the soldering joint.
N/a
N/a
N/a
N/a
Pin
Enable/disable pin prompt.
N/a
N/a
Beep
Enable/disable the beep
N/a
11
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm
130 mm
para manuales - color gris
200 mm
300 mm
Содержание CP-9QF
Страница 1: ...INSTRUCTION MANUAL CP Precision Rework Station ...
Страница 16: ...Notes 16 ...
Страница 17: ...Notes 17 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm ...
Страница 18: ...Notes 18 ...