background image

Clean  

periodically

Before carrying out maintenance, always allow the equipment to cool.

- Clean the station screen with a glass cleaner or  a damp cloth.

- Use a damp cloth to clean the casing and the 

tool. Alcohol can only be used to clean the 
metal parts.

- Periodically check that the metal parts of the 

tool and stand are clean so that the station 
can detect the tool status. 

- Maintain tip surface clean and tinned prior to 

storage in order to avoid tip oxidation.  
Rusty and dirty surfaces reduce heat transfer 
to the solder joint.

- Periodically check all cables and tubes.

Maintenance

Replace the blown fuse as follows.

1.

 Pull off the fuse holder and remove the fuse. If necessary use a tool to lever it off.

2. 

Insert the new fuse into the fuse holder and return it to the station.

- Replace any defective or damaged pieces. Only use original JBC spare parts. 

- Repairs should only be performed by a JBC authorized technical service.

*The 

Earthing Fuse

 minimize the risk of damaging the equipment when the tip touches a part with 

an active voltage. If the Earthing Fuse is blown, the station will show a message indicating that the 
fuse needs to be replaced. 

Be aware that if the station keeps working in this conditions, the tip to ground resistance would not 
meet the specifications.

Earthing Fuse *

Imput Fuse

14

Содержание CDE-BA Series

Страница 1: ...Compact Soldering Station Ref CDE BA INSTRUCTION MANUAL www jbctools com...

Страница 2: ...401 230V Manual 1 unit Ref 0020588 CDE Control Unit 1 unit Ref CDE 1BA 120V CDE 2BA 230V CDE 9BA 100V Brass Wool 1 unit Ref CL6210 Cartridges 2 units Ref C245903 x1 C245741 x1 Sponge 1 unit Ref S0354...

Страница 3: ...als Power Socket Input Fuse Main switch Pedal connector Features General Purpose Handle Ref T245 A Cable collector Quick Tip Changer Cartridge storage Tip Cleaner brass wool with antisplash membrane P...

Страница 4: ...rea is free of cable Tip Cleaner Select the option to suit your needs and improve the thermal transfer of the tip Splashguard Ref 0017576 It prevents splashing of solder particles when using the brass...

Страница 5: ...ing of the tip Metal Brush Ref CL6220 When used carefully it provides a more thorough cleaning Sponge Ref S0354 Tapping Tap gently to remove excess solder Wiping Use the slots to remove remaining part...

Страница 6: ...ut switching the station off 1 Removing 2 Inserting 3 Fixing Place the handpiece in the extractor and pull to remove the cartridge Place the handpiece on top of the new cartridge and press down slight...

Страница 7: ...from your PC Organize groups of stations and set all their parameters at the same time Store specific configurations for later uses Analyze the soldering graphics of the stations on your PC and export...

Страница 8: ...erature As a result tip life increases up to 5 1 Work 2 Sleep 3 Hibernation When the tool is lifted from the stand the tip will heat up to the selected temperature When the tool is in the stand the te...

Страница 9: ...0105 Menu Options Information Change port Station Tools Counters Reset Graphics Peripherals Press INFO for each parameter description USB flash drive is connected Station is controlled by a PC Station...

Страница 10: ...eal time are displayed for each port This helps you decide which tip to use to obtain the best quality solder joints Process analysis Graphics Temperature Power Export graphics Insert a USB flash driv...

Страница 11: ...g HMP or plastics e g riveting In most cases working with temperatures over 400 C 750 F can damage the PCB and its components Even in short time periods of tip contact with the soldering joint the flu...

Страница 12: ...o change the temperature This allows a quick change between 3 different tempe ratures Set them according to the allowed values for your soldering applications Because our tools reach the working tempe...

Страница 13: ...ype and then the user changes the cartridge for a C245030 which is thinner without resetting they would be working at a temperature of 20 C 36 F lower for the C245030 which does not need any temperatu...

Страница 14: ...cables and tubes Maintenance Replace the blown fuse as follows 1 Pull off the fuse holder and remove the fuse If necessary use a tool to lever it off 2 Insert the new fuse into the fuse holder and re...

Страница 15: ...e appliance unattended when it is on Do not cover the ventilation grills Heat can cause inflamable products to ignite Avoid flux coming into contact with skin or eyes to prevent irritation Be careful...

Страница 16: ...Pb Hg Cd Cr VI PBB PBDE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O O O X O O O O O O GB T 26572 X GB T 26572 16...

Страница 17: ...Exploded View www jbctools com 17...

Страница 18: ...Notes 18...

Страница 19: ...www jbctools com 19...

Страница 20: ...egister your warranty within 30 days of purchase in www jbctools com productregistration Specifications CDE 1BA 120V 50 60Hz Input fuse 2A Earthing fuse 1 25 A Output 23 5V Control Unit model CDE 1A C...

Отзывы: