Hibernation Delay
Set the time the tool will re-
main at Sleep temperature be-
fore entering the Hibernation
mode. At this time, the power
supply is cut off and the tip
remains at room temperature.
Tool Settings
Recommendations
Parameter description
Warnings
Increasing the default
value will accelerate
oxidation and shorten the
tip life.
When the user chan-
ges the cartridge type, the
parameter should be reset
to 0°C/F or to the value
needed for this cartridge.
E.g. If a correction of
+20°C (+36°F) is set for the
C245966 (thick type) and
then the user changes the
cartridge for a C245030
(which is thinner) without
resetting, they would be
working at a temperature
of +20°C (+36°F) lower for
the C245030 which does
not need any temperature
adjustment.
This function completely
protects the tip from oxidation
during long periods of inactivi-
ty while the tool is in the stand.
Retinning the tip before pla-
cing the tool in the stand also
helps prevent oxidation and
extends the life of the tip.
Temp Adjustment
It provides a more precise
adjustment between the
selected temperature and the
actual one.
Set values within ±50°C
(± 90°F) to achieve zero error.
JBC strongly recommends the
use of TID-A or TIA-A Ther-
mometers to obtain precise
readings.
32
Содержание CD-1SE
Страница 1: ...INSTRUCTION MANUAL 精密焊接台 Ref CD 2SHE English 22 Page 中文 2 www jbctools com ...
Страница 17: ...分解图 www jbctools com 17 ...
Страница 18: ...18 ...
Страница 19: ...Precision Soldering Station Ref CD 2SHE www jbctools com 19 ...
Страница 35: ...Exploded www jbctools com 35 ...