ENGLISH
USER MANUAL
JB SYSTEMS
®
8/44
LED MARVEL
While using an external DMX controller the 21CH DMX-chart can be used:
Channels 1 to 18 can be used to individually control the red, green and blue colors for the 6 panels, see
the chart for the exact information.
Channel 19 is the master dimmer for the 6 panels, see the chart for the exact information.
Channel 20 can be used to recall internal patterns, above DMX-value 247 channels 1 to 19 become active.
Channel 21 is used to set the speed of the internal patterns.
DMX channel
Value Range
Function
CH1
000-255
Panel1 (from top) R level
– only active if CH20 >248
CH2
000-255
Panel1 (from top) G level
– only active if CH20 >248
CH3
000-255
Panel1 (from top) B level
– only active if CH20 >248
CH4
000-255
Panel2 (from top) R level
– only active if CH20 >248
CH5
000-255
Panel2 (from top) G level
– only active if CH20 >248
CH6
000-255
Panel2 (from top) B level
– only active if CH20 >248
CH7
000-255
Panel3 (from top) R level
– only active if CH20 >248
CH8
000-255
Panel3 (from top) G level
– only active if CH20 >248
CH9
000-255
Panel3 (from top) B level
– only active if CH20 >248
CH10
000-255
Panel4 (from top) R level
– only active if CH20 >248
CH11
000-255
Panel4 (from top) G level
– only active if CH20 >248
CH12
000-255
Panel4 (from top) B level
– only active if CH20 >248
CH13
000-255
Panel5 (from top) R level
– only active if CH20 >248
CH14
000-255
Panel5 (from top) G level
– only active if CH20 >248
CH15
000-255
Panel5 (from top) B level
– only active if CH20 >248
CH16
000-255
Panel6 (from top) R level
– only active if CH20 >248
CH17
000-255
Panel6 (from top) G level
– only active if CH20 >248
CH18
000-255
Panel6 (from top) B level
– only active if CH20 >248
CH19
000-255
Master Dimmer CH1-CH18
– only active if CH20 >248
CH20
000-247
Preset Play Mode; value changes preset
248-255
DMX control mode, enables CH1-CH19
CH21
000-255
Preset Play Speed setting
– only active if CH20 >247
MAINTENANCE
This device does not need regular maintenance. It is protected by an internal fuse located on the power
supply PCB. If this fuse fails, this usually indicates an internal fault requiring servicing by a qualified
engineer. The fuse shall only be replaced by a fuse of same specification, and the replacement has to be
made by qualified personnel obeying applicable safety rules.
SPECIFICATIONS
Mains Input:
12Vdc / 1A
Power Adapter:
AC 90V ~ 250V, 50/60Hz to 12Vdc / 1A
Power consumption:
max. 12 Watt
Sound Control:
Internal microphone
DMX connections:
3,5mm stereo jack female
DMX channels used:
21 channels
LEDs:
216pcs (72 red + 72 green + 72 blue)
Size:
see drawing
Weight:
0,48kg
The information might be modified without prior notice
You can download the latest version of this user manual on our website:
www.beglec.com