ENGLISH
OPERATION MANUAL
JB SYSTEMS
®
4/4
FAZE-700
MAINTENANCE
IMPORTANT:
Always put the [Volume] knob of the remote controller to Zero output and wait for about 1 to
2 minutes before to switch off the unit. This allows the unit to start up its cleaning process so all the
remaining fluid is removed from the internal circuits. If you are not using the remote controller, then select
[HAZE] on the control board via the [MENU] button and also wait for about 1 to 2 minutes before to switch
off the unit.
Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
This unit is radio-interference suppressed. This product meets the requirements of the current European and
national guidelines. Conformity has been established and the relevant statements and documents have been
deposited by the manufacturer.
This device has been designed to produce decorative effect lighting and is used in light show systems.
Mains Input:
AC 230V, 50Hz
Power consumption:
700 Watt
DMX Channels:
No DMX on board
Fuse:
T8A/250V (slow blow 6x30mm)
Output:
+/- 1400 cubic ft/min
Warm up time:
3 min
Tank size:
1,2L
Recommended Fluid:
JB Systems Standard or Hi-Tech Fog Liquid
Size:
300 x 147 x 290 mm
Weight:
5 kg
All the information is subject to change without prior notice