ENGLISH
OPERATION MANUAL
JB SYSTEMS
®
3/4
FAZE-700
3. POWER SWITCH:
Used to switch the power of the unit on/off.
4. INPUT FUSE:
When the fuse is blown, first locate and solve the problem that caused the fuse to blow.
When the problem is solved, replace a damaged fuse with a fuse of the same type and electrical
specifications. (250V-8A)
5. MAINS CABLE:
to be plugged in a mains wall socket with earth connection.
6. FOG FLUID CONTAINER:
to be filled with CE-certified smoke fluid. Make sure that the fog fluid
container is never empty during operation; this will damage the pump of the fogger.
7. FLUID LEVEL INDICATOR:
Used to monitor the remaining quantity of fog fluid. Note that if you use the
fogger without fluid, the internal pump will be damaged!
8. FOG OUTPUT:
DANGER: this nozzle can be very hot and can sometimes leak some hot liquid. Keep a
distance of at least 1meter !
9. FAN:
This fan runs at constant speed and ensures a better dissipation of the smoke.
REMOTE CONTROLLER:
1. [OUTPUT] KNOB:
this knob is used to set the volume of the
continuous fog output
2. [POWER] LED:
when the unit is on, this Led will be lit.
3. [READY] LED:
when this Led is lit, it means the machine is
ready to produce fog. When you have just turned on the power
of the unit, you will have to wait for a couple of minutes till the
heater is warm enough before this Led will be lit.
4. ON/OFF BUTTON:
used to switch the fog control on/off:
OPERATING INSTRUCTIONS
Put the fogger on a flat and very stable surface. Make sure that nobody can put their hands just in front of
the output. The fog is very hot and can cause serious burnings!!!
Make sure the fog liquid tank is not empty. Always use good quality fog liquid to fill up the tank. Close the
tank immediately to prevent dirt to enter the reservoir!
Plug the supplied remote in the [remote control] input on the back of the unit.
Make sure to plug the fogger in a mains wall socket with earth connection
Switch the fogger on and wait for about 3 minutes. (warm up time)
When the fogger is ready, use the control panel to select the desired continuous fog output.
If you want to use the remote controller, you need to select [StOP] on the control panel of the fogger.
(Otherwise, the machine will continue its selected program you have set in the control panel menu).
Plug the supplied remote in the [remote control] input on the back of the unit.
You can now use the remote control.
IMPORTANT:
DO NOT just turn off the power or remove the power cord when you want to interrupt or
stop the production of fog
. Always put the menu of the control panel on [StOP] or set the [Volume] knob of
the remote to “zero”. This will allow the unit to start up the cleaning procedure and remove the remaining fog
liquid from the internal circuits. If you
don’t want to produce fog anymore and decide to switch off the unit;
wait for about 1 minute so the total cleaning is finished before to switch the unit off or before to disconnect
the unit from the mains.