32
JB-lighting Lichtanlagentechnik GmbH Sallersteigweg 15 D-89134 Blaustein T49 (0)7304-9617-0
5. Service
5.1 Cleaning the fixture
To ensure a long and satisfying performance of the fixture, check function of the fans
in the head and in the base from time to time. Most important: make sure that there
is no dust or fluff covering the air inlets. To clean the fixture open lid of the head and
the baseplate. Use a brush and a vacuum cleaner to remove dust and fluff. Don´t
damage or bend any parts. Incompetend performace of the maintenance will invalidate
the warranty claims. Consult qualified service personnel.
WARNING: Disconnect fixture from mains, and allow unit to cool
down for at least 10 minutes!
With direct view on the beam source use a welding
goggle of reduction 4-5!
!
5.2 Changing of the lens module
There are two lens modules with different beam angles available. The standard beam
angle is 10° the optional lens module offers a 25° beam angle. To change the modules
remove the 4 cross-heades screws on the front of the lens module and remove the
complete lens module. Please don´t touch the lenses, if necessary use cotton gloves.
Insert the optional module paying attention to the orientation of the reflector-clips which
should face the base.
remove
cross-head screws
reflector-clip