8.6 Cleaning the device

You should check the function of the fans in 
the head and foot at regular intervals. Above all, 
make sure that the air intakes and the interior 
of the P9 Beamspot are free of fluff and dust.
To do this, open the head cover (4x camlocks 
with half a turn) and the base plate on the foot. 
You can clean the P9 Beamspot with a brush and 
a vacuum cleaner. In addition, you can remove 
the gobo insert (1) and the shutter slide insert (2) 
by loosening the knurled screws (3) and sliding 
the focus carriage towards the lens. Then you 
can clean the colour filters, glass gobos and 
CMY panes with a soft cloth and a little window 
cleaner. To clean the frost flaps, prisms and 
zoom/focus unit, remove the four Phillips screws 
(4) and then the cover. Ensure that you do not 
bend or damage any parts during cleaning. When 
cleaning is complete, reconnect the flap, replace 
the Phillips screws (4) and return the inserts to the 
unit.

WARNING: Disconnect fixture before opening!

!

8.7 Service and maintenance

On the P9 Beamspot, the zoom / focus guide rails and the rotating gobos should be checked 
for sufficient lubrication at regular intervals - once a year. To do this, open the head cover (4x 
camlocks with half a turn), the zoom cover (3 Phillips screws) see (4) and remove the gobo insert 
(2 knurled screws).
Please note that the rotating gobos and the guide rails do not run dry; if necessary, the rotating 
gobos must be oiled with a special syringe and the guide rails with a brush with our special sil-
icone oil.
After the gobos and the rails have been checked or oiled, reinsert the slot and close the zoom 
cover again. After completing the work, replace the head cover on the headlight and test all the 
functions of the headlight.

Содержание P9 Beamspot

Страница 1: ...Operating instructions Version 1 04 Software 1 0 0 P9 Beamspot...

Страница 2: ...02 P9...

Страница 3: ...5 PERSONALITY Personal settings 18 6 6 STANDALONE operation 21 6 7 INFO menu 22 6 8 Shortcuts quick access 22 7 Control options 23 7 1 DMX 23 7 1 1 Operating modes P9 Beamspot 23 7 1 2 DMX channel fu...

Страница 4: ...04 P9...

Страница 5: ...00 K 5800 K 3200 K Luminosity 25 000 lm 15 000 lm output 10 000 lm output 7 500 lm output CRI 70 90 85 1 Introduction 1 1 P9 Beamspot models The P9 beam spot is available in the light color HP High Po...

Страница 6: ...t Art Nr Datum Pris Fax 07304 9617 99 Tel 07304 9617 0 P9 kuehngruen Allgemeintoleranzen ISO 2768 m Blechdicke Material Farbe Oberfl che Abmessung Lichtanlagentechnik GmbH Sallersteig 15 89134 Blauste...

Страница 7: ...rCON TRUE1 Input Bottom cover Top cover Arm cover Handles LCD display Function keys Material Abmessung Name Erstellt Art Nr Datum Prisma Fax 07304 9617 99 Tel 07304 9617 0 P9 kuehngruen Allgemeintoler...

Страница 8: ...fuses or parts The mains plug must always be accessible after the spotlight has been installed Do not overload the sockets or extension cables as this could result in fire or electric shock Do not pla...

Страница 9: ...evice Avoid brute force during installation or operation This light was designed for indoor use only Do not expose this device to rain or moisture When choosing a mounting location make sure that the...

Страница 10: ...ghtcasesifthedeviceistobetransported When using the original packaging the locks must not be closed ATTENTION Only have plugs installed by a specialist The P9 Beamspot is supplied with an assembled Sc...

Страница 11: ...ated or a DMX signal is present Connection outside Europe The P9 Beamspot may only be operated on the following power supply systems Mains P9 2 wires 1 phase L N L N PE 3 wires 1 phase L N L L N 4 wir...

Страница 12: ...cabling can be done with standard network lines The sockets on the device are Neutrik etherCON sockets Special cables with etherCON connectors are recommended by Neutrik The two sockets on the P9 Bea...

Страница 13: ...223 65mm When placing the unit on the floor make sure that it stands on rigid ground because the air inlets in the base must not be covered with anything 140 223 65 140 1 2 4 3 To mount the unit on a...

Страница 14: ...enu or confirms an input ESC is used to exit a function or a menu item UP and DOWN are used to navigate within the menu and to enter values Special areas can only be called up using a specific key com...

Страница 15: ...ll in it but has already been confirmed or was automatically confirmed Only when the error has been deleted from the ERROR LIST does the P9 Beamspot start again without error signalling If errors occu...

Страница 16: ...T FLEX FAST DMX ADDRESS ADDRESS ARTNET ADDRESS DMX MODE MODE 1 MODE 2 ON OFF DEFAULT IP NETWORK 10 NETWORK 2 USER IP BYTE 1 BYTE 2 BYTE 3 BYTE 4 ADDRESS ADDRESS ADDRESS ADDRESS SURE WIRELESS IP ADDRES...

Страница 17: ...E FADE TIME NEXT TIME NEXT TIME PAN PAN TILT TILT CONTROL CONTROL SHUTTER SHUTTER DIMMER DIMMER FOCUS FOCUS ZOOM ZOOM IRIS IRIS GOBO1 GOBO1 GOBO2 GOBO2 GOBO2 ROT GOBO2 ROT COLOR CYAN MAGENTA COLOR CYA...

Страница 18: ...ddress is displayed in the form 00000 6 5 PERSONALITY Personal settings DMX INPUT CONFIG In this menu item the options WIRELESS and NETWORK are available Under WIRELESS ON OFF the factory installed ra...

Страница 19: ...htness is always the same level STANDARD from an ambient temperature of approx 36 C the fans run to cool the LED accord ingly The brightness remains constant BOOST Brightness 15000 lm the fans run a l...

Страница 20: ...ges are possible BACKLIGHT MODE setting the display backlight This menu item controls the backlight of the display OFF The backlight of the display is always off The lighting only switches on when a b...

Страница 21: ...and position and determine the individual sequence times of the steps with FADE TIME and NEXT TIME time for the complete step Use INSERT to insert an additional programming step The DMX values of the...

Страница 22: ...ambient temperature Both the current temperature and the maximum temperature are displayed The maximum temperatures can be individually deleted 6 8 Shortcuts quick access ESC DOWN Pressing the ESC and...

Страница 23: ...l 13 Gobo 1 Autofocus distance Channel 14 Gobo 2 Reserved Channel 15 Gobo 2 rotation Iris Channel 16 Colour wheel Fine iris Channel 17 Cyan Gobo 1 Channel 18 Magenta Gobo 2 Channel 19 Yellow Gobo 2 ro...

Страница 24: ...thing Dimmer fade out via fader fast slow not used Setting for medium DMX smoothing Dimmer fade out via fader fast slow not used Setting for medium maximum DMX smoothing Dimmer fade out via fader fast...

Страница 25: ...E selection of dimming out STANDARD SOFT not used COOLING MODE Adjust the fan volume and brightness This takes place with dimmer shutter set to closed DMX 000 then after 2 seconds the fixture will swi...

Страница 26: ...Shutter open Random shutter fade 100 rapid slow Shutter open 000 015 016 095 096 110 111 111 112 125 126 126 127 126 128 142 143 143 144 158 159 159 160 174 175 175 176 190 191 191 192 206 207 207 208...

Страница 27: ...9 Gobo 10 Gobo 11 Gobo wheel rotation fast slow Gobo wheel rotation fast slow 016 023 024 031 032 039 040 047 048 055 056 063 064 071 072 079 080 087 088 191 192 223 224 255 15 20 Gobo wheel 2 rotatin...

Страница 28: ...gobo on White color shift gobo off White CTB CTB CTB Red Red Red Yellow Yellow Yellow Magenta Magenta Magenta Green Green Green Orange Orange Orange Blue Blue Blue Pink Pink Pink CRI CRI CRI CTO CTO...

Страница 29: ...rotation Prism positioning 0 540 Prism rotation right rapid slow Stop prism rotation Prism rotation left slow rapid 000 191 192 222 223 224 225 255 38 Prism 1 fine positioning rotation 16 Bit 000 255...

Страница 30: ...dingly to 125 32000 Then set the distance to the headlight by focusing the headlight using the autofocus distance As a guideline DMX value divided by 10 corresponds to the distance DMX 100 10 distance...

Страница 31: ...DM The P9 Beamspot can communicate via RDM Remote Device Management in accordance with ESTA American National Standard E1 20 2006 RDM is a bidirectional communication protocol for use in DMX512 contro...

Страница 32: ...DM configuration DEVICE_MODEL_DESCRIPTION MANUFACTURER_LABEL FACTORY_DEFAULTS SOFTWARE_VERSION_LABEL DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION DMX_START_ADDRESS SENSOR_DEFINITION DEVICE_HOURS LAMP_H...

Страница 33: ...ST This menu item is used to test the DMX input Use the function keys to select the DMX channel to be tested The display shows the incoming value at the same time the P9 Beamspot reacts accordingly IN...

Страница 34: ...hange the rotating gobos remove only the clamping ring A with a pointed object replace the gobo and then put the clamping ring again When installing glass gobos make sure the white coated side faces t...

Страница 35: ...amspot as soon as the message Insert USB stick appears on the display release the key Now plug in the USB stick on the back of the device below the signal connections and follow the instructions on th...

Страница 36: ...er Ensure that you do not bend or damage any parts during cleaning When cleaning is complete reconnect the flap replace the Phillips screws 4 and return the inserts to the unit WARNING Disconnect fixt...

Страница 37: ...OUT Blade4A BLADE4B TIMEOUT Blade4B ZOOM TIMEOUT Zoom FOCUS TIMEOUT Focus PRISM1 TIMEOUT Prism 1 linear PRISM1ROT TIMEOUT Prism 1 rotation PRISM2 TIMEOUT Prism 2 circular PRISM2ROT TIMEOUT Prism 2 rot...

Страница 38: ...R High Temperatur Base Air SPARX ONLY HIGH TEMP BPS High Temperature Base PSU AC DC HIGH TEMP HMAIN High Temperature Head Main PCB HIGH TMP HDRV High Temperature Head LED Driver PCB HIGH TMP H LED Hig...

Страница 39: ...uminous intensity HP 25000 Lumen 20 C Effects Pan 546 74 Tilt 281 16 Zoom 3 4 54 Construction Colour black Housing PC ABS Protection class IP 20 Plug in technology yes Installation Installation site i...

Страница 40: ...ds Limit value class A Radiation Information technology equipment radio interference characteristics EN 55032 2015 Limit values and measuring methods Limit value class A Harmonic currents Electromagne...

Страница 41: ...41 P9...

Страница 42: ...42 P9...

Страница 43: ...43 P9...

Страница 44: ...JB Lighting Lichtanlagentechnik GmbH Sallersteig 15 89134 Blaustein Tel 49 7304 9617 0 Fax 49 7304 9617 99 info jb lighting de www jb lighting de...

Отзывы: