- 36 -
P9
22
11
33
8.6 Cleaning the device
You should check the function of the fans in
the head and foot at regular intervals. Above all,
make sure that the air intakes and the interior
of the P9 Beamspot are free of fluff and dust.
To do this, open the head cover (4x camlocks
with half a turn) and the base plate on the foot.
You can clean the P9 Beamspot with a brush and
a vacuum cleaner. In addition, you can remove
the gobo insert (1) and the shutter slide insert (2)
by loosening the knurled screws (3) and sliding
the focus carriage towards the lens. Then you
can clean the colour filters, glass gobos and
CMY panes with a soft cloth and a little window
cleaner. To clean the frost flaps, prisms and
zoom/focus unit, remove the four Phillips screws
(4) and then the cover. Ensure that you do not
bend or damage any parts during cleaning. When
cleaning is complete, reconnect the flap, replace
the Phillips screws (4) and return the inserts to the
unit.
WARNING: Disconnect fixture before opening!
!
8.7 Service and maintenance
On the P9 Beamspot, the zoom / focus guide rails and the rotating gobos should be checked
for sufficient lubrication at regular intervals - once a year. To do this, open the head cover (4x
camlocks with half a turn), the zoom cover (3 Phillips screws) see (4) and remove the gobo insert
(2 knurled screws).
Please note that the rotating gobos and the guide rails do not run dry; if necessary, the rotating
gobos must be oiled with a special syringe and the guide rails with a brush with our special sil-
icone oil.
After the gobos and the rails have been checked or oiled, reinsert the slot and close the zoom
cover again. After completing the work, replace the head cover on the headlight and test all the
functions of the headlight.