CHIMNEY CLEANING AND CHECKING FLUES

For all wood fi res, fl ue cleaning must be done regularly to avoid serious fl ue fi res. Frequently used fi res 
should be cleaned at least once a year (some sooner). The cleaning rate, however, depends on the burning 
habits of the individual operating the wood fi re and the fuel used.

It is recommended that fl ue sweeping be done by a professional chimney sweep. Chimney sweeping is a 
specialist task and competent professional sweeps are available throughout the country. When the fl ue is 
cleaned it is recommended that other parts, such as baffl es and ceramic insulation materials are checked.
Flue systems should be checked at least once or twice a heating season and may require checking more 
often if the fuel or operation of the appliance is incorrect. When a fl ue system becomes excessively blocked 
or requires frequent cleaning, advice should be sought to investigate the installation and the operation of 
the fi re. Flue pipes can deteriorate very quickly with incorrect fi ring. 

CONSUMABLES

Some parts of your UL200  fi re are considered consumable. They are designed to be replaced as they will 
degrade over time. The life of the consumables will vary depending on;
 

•  How often the fi re is used

 

•  Type of fuel. Some woods are much harsher than others

General items that are considered consumables:
 

•  Baffl es

 

•  Fire Bricks

 

•  Glass and door ropes

 

•  Downdraft cylinder and downdraft cassette

It is very important that you replace these parts when they show signs of wear. They effect how the fi re runs 
and you may increase your fuel consumption or lower your effi ciency if not replaced and can in some cases, 
damage the fi rebox. It is generally obvious once a part is in need of replacement. Steel components may 
split or large holes may appear, fi re bricks may crack and disintegrate. We recommend you check your fi re 
visually several times a year for damaged components. 

JAYLINE WARRANTY SERVICE INTERVALS

Jayline UL200 comes with an initial 5 year fi rebox warranty. This warranty is validated every 5 years 
to a maximum 15 year fi rebox warranty subject to a technicians service pack update. This ensures all 
consumable items have been inspected and replaced if required, and also notifi es Jayline that your service 
records are current. Evidence of service pack update will be required in the event of a claim.

To order your service pack or for more information see www.jayline.co.nz or your local Jayline retailer.

See Page 12 for warranty details. 

Содержание UL200

Страница 1: ...UL200 FREESTANDING WOOD FIRE INSTALLATION OPERATION INSTRUCTIONS October 2014 June 2018 Please leave this information with the appliance...

Страница 2: ...Consequently the use of wood as fuel maintains the perfect equilibrium of nature because it is a renewable fuel of which burning is comparable with nature s life cycle The principle of clean combustio...

Страница 3: ...ather and eliminate smoke spillage problems due to lack of draught 3 Ascertain suitable position for appliance and size of oor protector and check the ceiling to ensure that no major structural member...

Страница 4: ...ue system into ue spigot with stainless steel self tapping screws 10 Drill and secure the appliance to the oor protector using the two holes in the rear bracket of the appliance FITTING SEISMIC RESTR...

Страница 5: ...hieve a clearance factor of 0 30 Two spaced Layers of continuous material with minimum Air Gap of 12mm 12mm to achieve a clearance factor of 0 20 The shielding must be open at the top and bottom vente...

Страница 6: ...People with respiratory heart or other relevant medical conditions should avoid inhaling vapours during the curing process All VHT paint will cure at the highest temperature achieved and will produce...

Страница 7: ...forward the UL200 can be operated much like a traditional wood re due to its automatic functions Ensure the entire fuel load ts inside the rebox before closing the door The optimum fuel length is 300m...

Страница 8: ...R ZONES Firewood should be cut and split in the early spring and stacked under cover with good ventilation to be ready for burning when required Look for cracks in the end grain as a sign of dry wood...

Страница 9: ...ecautions must be taken prior to cleaning a Make sure all parts of the re are cold b Make sure the ashes are completely cold and not burning c Always use the most appropriate tools and items supplied...

Страница 10: ...they will degrade over time The life of the consumables will vary depending on How often the re is used Type of fuel Some woods are much harsher than others General items that are considered consumab...

Страница 11: ...TED WITH CRACKED GLASS CAUTION DO NOT USE THE FIRE IF THERE IS A MALFUNCTION A SUSPICION OF BREAKAGE OR UNUSUAL NOISES CAUTION NEVER THROW WATER ON THE FIRE WHEN IN USE OR USE WATER TO EXTINGUISH THE...

Страница 12: ...the same time any other minor potential problems can be detected and corrected before they turn into major ones We think this is a small price to pay to ensure your heater is kept in peak condition T...

Страница 13: ...by a failure or defect covered in this guarantee All claims in the first instance should be directed to the store of purchase Any repairs undertaken without the manufacturer s authority will render th...

Страница 14: ...ndition of the fire box check or replace the firebricks if necessary check combustion plates and replace if necessary check and replace air tubes if fitted required check and replace glass and door se...

Страница 15: ...page 15 www jayline co nz JUNE 2018...

Страница 16: ...____________________________________________________________________________ EMAIL ________________________________________ PHONE ________________________ MODEL _______________________________________...

Страница 17: ...page 17 www jayline co nz JUNE 2018...

Отзывы: