Section 8: Plumbing System
Turn the
Electric Hot Water switch ON
. This activates the 120 Volt-AC electric heating
element and the indicator light located on the
switch. Allow 1-2 hours for the Aqua-Hot
System to reach operating temperature.
Zone Thermostat Operation
Interior Room Thermostat:
Adjust each interior room thermostat to the desired temper-
ature. Whenever an interior room thermostat “calls for heat,” the Aqua-Hot’s circulation
pump and interior heat exchanger fans will be activated. Aqua-Hot must be at operating
temperature in order for the zones to function.
Using the Domestic Hot Water System
When the Aqua-Hot is at operating temperature, the domestic water is automatically heated
as it is being used. The Aqua-Hot system is tankless and does not store any hot water, con-
tinuous hot water will be present from any faucet. The Diesel-Burner switch must be
ON
in order to obtain a continuous supply of hot water; activate the electric element switch for
maximum
hot water capacity.
NOTE: The Aqua-Hot’s “Domestic Water Priority System” disables the inte-
rior zone heating fans and the zone circulation pumps whenever domestic hot
water is being used on a continuous basis. Once the demand for continuous
hot water ceases, the Aqua-Hot will enable the fans and the pumps to operate
and provide heat to the heating system.
NOTE: Both the Diesel-Burner and the electric heating element are thermo-
statically controlled. Either, or both heating sources will automatically main-
tain the temperature of the antifreeze and water heating solution between
approximately 160°F and 190°F (±5).
To heat the motor home/domestic hot water, choose the desired heat source(s) and leave the
switch(s) (burner and/or
electric hot water) ON.
Electric Hot Water:
When connected to shore power or when using the generator, the
Aqua-Hot electric heating element has the ability to function in order to provide heat for the
boiler tank.
The electric heating element is a
secondary heat source
for heating both the interior and the
domestic hot water during low heating demand situations (moderate ambient temperatures
exist and/or when there is a low demand for domestic hot water).
Maintenance (Aqua-Hot)
Refer to the Aqua-Hot owner’s manual for detailed procedures, system requirements
and parts information prior to performing any maintenance to the Aqua-Hot system.
Monthly Maintenance
Check the Aqua-Hot’s antifreeze and water heating solution to ensure that it is at the proper
level. This can be accomplished by visually checking the coolant level in the Aqua-Hot’s ex-
pansion tank. The coolant level should be checked
only
when the Aqua-Hot is at maximum
operating temperature (i.e., immediately after the Diesel-Burner cycles OFF). When the
Aqua-Hot is at maximum operating temperature, the antifreeze and water heating solution
should be at the level marked “HOT” on the expansion tank.
When the Aqua-Hot is at maximum operating temperature, the coolant will be
very HOT! If Aqua-Hot’s heating system is accessed, scalding by hot vapor
or coolant could result! Before cleaning or servicing, disconnect all power
supplies!
Table of Contents
Содержание SENECA PRESTIGE 2023
Страница 1: ...2023 OWNER S MANUAL A subsidiary of Thor Industries Inc SENECA PRESTIGE ...
Страница 2: ......
Страница 20: ...14 Section 1 Warranty Service Notes Table of Contents ...
Страница 32: ...26 Section 3 Pre Travel Information Notes Table of Contents ...
Страница 50: ...44 Section 4 Vehicle Operation Notes Table of Contents ...
Страница 58: ...52 Section 5 Slideout Systems Notes Table of Contents ...
Страница 76: ...70 Section 7 Fuel Propane System Notes Table of Contents ...
Страница 104: ...98 Section 9 Heating Cooling Notes Table of Contents ...
Страница 126: ...120 Section 13 Exterior Notes Table of Contents ...
Страница 130: ...124 Section 14 Travel Camping Storage Checklists Notes Table of Contents ...
Страница 134: ...128 Section 15 Additional Information Notes Table of Contents ...