Section 8: Plumbing System
3.
Empty the tanks one at a time. Empty the black tank first
followed by the gray tank so waste water from the gray
tank will help rinse solids or debris from the dump con-
nector and flex hose.
Electric system
: To open the black or grey tank drain
valve, press the corresponding tank drain (rocker)
switch. To close the valve, press the switch again.
Manual system:
To open the black or grey tank
drain valve, pull the corresponding T-handle out.
Close the drain by pushing in the T-handle in.
4.
Turn the Macerator power switch ON at the utility center panel and the macerator pump
will begin sending waste through the dump hose.
Make sure the sewer hose is con-
nected before turning the macerator on
.
5.
When the tank is empty, turn the macerator power switch OFF. Close the black tank
drain valve.
6.
Select the gray drain valve.
7.
Turn the Macerator Power Switch ON.
8.
When tank is empty, turn the macerator power switch OFF. Close the gray tank drain
valve.
9.
Unhook the dump connector, rinse it out and replace the hose and connector back into
the storage compartment.
The black tank flush inlet can also be used with this system (refer to the
Black Tank Flush
section).
Macerator Bypass Valve
In the event the macerator pump malfunctions, there is a macerator bypass valve. Depend-
ing on your model, this valve may be located in the utility center, in the compartment with
the black/gray tank valves or under the motor home (accessible through the generator com-
partment). This bypass will dump the waste (using gravity flow) from the black/gray tanks
to a 3-inch sewer hose connection.
To operate:
1.
Attach a 3-inch sewer hose to the bypass connection , and
to a sewer outlet at a dump station.
2.
Empty the tanks one at a time. Black tank should be emp-
tied first followed by the gray tank so waste water from
the gray tank will help rinse solids or debris from the
dump outlet and hose.
3.
Pull the black tank dump valve located.
4.
Pull the manual macerator bypass valve to open it and the black tank will empty by
gravity flow.
5.
Close the black tank dump valve, and then close the macerator bypass valve.
6.
Open the gray tank dump valve, and then open the macerator bypass valve.
7.
When finished, make sure both black and gray tank dump valves are closed, shut off
the macerator bypass valve, and disconnect the sewer hose from the motor home and
at the dump station.
8.
Clean and store the sewer hose.
9.
Replace the dust cap on the macerator bypass.
The black tank flush inlet can be used with the macerator bypass (refer to
the
Black
Tank
Flush
section).
Table of Contents
Содержание SENECA 2023
Страница 1: ...2023 OWNER S MANUAL A subsidiary of Thor Industries Inc SENECA...
Страница 2: ......
Страница 20: ...14 Section 1 Warranty Service Notes Table of Contents...
Страница 32: ...26 Section 3 Pre Travel Information Notes Table of Contents...
Страница 54: ...48 Section 4 Vehicle Operation Notes Table of Contents...
Страница 62: ...56 Section 5 Slideout Systems Notes Table of Contents...
Страница 84: ...78 Section 7 Fuel Propane System Notes Table of Contents...
Страница 108: ...102 Section 8 Plumbing System Notes Table of Contents...
Страница 136: ...130 Section 14 Travel Camping Storage Checklists Notes Table of Contents...
Страница 140: ...134 Section 15 Additional Information Notes Table of Contents...