96
Section 8: Plumbing System
COMFORT MODE:
The appliance is running in a mode
that provides rapid availability of hot water. Water tem-
perature at the fixtures is 120°F (49°C).
System is operating in Stand By Heat, which keeps water
temperature in the appliance at 102°F (39°C). While run-
ning in COMFORT MODE the yellow status LED (3) on
the rotary dial will be lit.
When the power switch is OFF, the appliance is not run-
ning in any operating mode. Yellow status LED (3) on the
rotary dial is NOT lit.
ANTIFREEZE: (Snowflake / Lightning bolt)
Preven-
tion of freezing using 12VDC electricity. If the acces-
sory electric antifreeze kit is installed, and the appliance
switched ON, the temperature in the water heater is au-
tomatically held above 41°F (5°C). During operation the
yellow status LED (3) is lit.
CLEAN: (Decalcification)
This mode is only available on the Aqua Go COM-
FORT or COMFORT PLUS models. For safety reasons after 30 seconds the de-
calcification process cannot be stopped until the system has been rinsed (Refer to
Decalcification and Rinsing the System)
.
Draining the Aqua Go Water Heater
The Aqua Go water heater does not have a conventional
drain plug. Instead it includes a “drain chute”.
Water heater power should be OFF, water pump
OFF, and fixtures open to relieve pressure on
the plumbing system.
DO NOT DRAIN THE
WATER HEATER IF IT IS HOT OR UN-
DER PRESSURE!
Open the water heater exterior door to the “ser-
vice” position hanging by the straps.
Open the drain chute by pushing UP on the
black button above the yellow label on the left
side of the water heater (
A
). This releases the
drain chute.
Push the chute all the way open which will
dump water out of the water heater away from
the side of your RV. Water heater contains ap-
proximately 1.5 liters of water.
Drain all the water out of the water heater.
The water inlet filter is located inside the drain
chute (
B
). The filter will pull out of the open
-
ing in the drain chute. Rinse it with clean water,
inspect O-rings for cracks.
To close the drain chute, push it up until it
latches back into place. You will hear an audible
“click” when the chute engages.
NOTE: If the inlet filter is difficult to re-install, use
a small amount of soap on the O-rings. NEVER USE
GREASE as the O-rings are not resistant to grease.
Table of Contents
Maintenance Record
Содержание MELBOURNE 2023
Страница 1: ...2023 OWNER S MANUAL A subsidiary of Thor Industries Inc MELBOURNE MELBOURNE PRESTIGE...
Страница 2: ......
Страница 20: ...14 Section 1 Warranty Service Notes Table of Contents Maintenance Record...
Страница 32: ...26 Section 3 Pre Travel Information Notes Table of Contents Maintenance Record...
Страница 50: ...44 Section 4 Vehicle Operation Notes Table of Contents Maintenance Record...
Страница 58: ...52 Section 5 Slideout Systems Notes Table of Contents Maintenance Record...
Страница 118: ...112 Section 10 Appliances Notes Table of Contents Maintenance Record...
Страница 120: ...114 Section 11 Electronics Notes Table of Contents Maintenance Record...
Страница 128: ...122 Section 12 Interior Notes Table of Contents Maintenance Record...
Страница 134: ...128 Section 13 Exterior Notes Table of Contents Maintenance Record...
Страница 138: ...132 Section 14 Travel Camping Storage Checklists Notes Table of Contents Maintenance Record...
Страница 142: ...136 Section 15 Additional Information Notes Table of Contents Maintenance Record...