SECTION 8-PLUMBING SYSTEMS JAYCO TOWABLE
Pilot outage caused by burner lift-off or sooting from a yellow burner may occur,
indicating the possibility of carbon monoxide.
You may also notice a lack of efficiency in heating the water because of incomplete
combustion of the burner at these higher altitudes.
Consult with the local propane company, your dealer or the water heater manufacturer for
proper derating of the water heater. Change out of the orifice (derating) should be done by
the dealer or a qualified service agency.
NOTE
: It is important that once the RV has returned to lower elevation (below 4500
feet) any high altitude deration or other adjustments be reversed for proper operation of the
water heater.
Pressure & temperature relief valve
The temperature and pressure relief valve is designed to open if the temperature of the
water within the heater reaches 120° F, or if the water pressure in the heater reaches 150
pounds. When this pressure is reached, the pressure relief valve will open and water will
drip from the valve.
This “weeping” or dripping will continue until the pressure is reduced to below 150
pounds, and the valve closes. This condition is normal and does not indicate a defective
relief valve.
One way to reduce the frequency of this occurrence is to maintain an air pocket at the top
of the water heater tank. This air pocket will form in the tank by design; however, it will be
reduced over time by the everyday use of your water heater. To replenish this air pocket:
1.
Turn off the water heater.
2.
Turn off the cold water supply line.
3.
Open a faucet in the recreation vehicle.
4.
Pull out the handle of the pressure relief (P&T) valve and allow water to flow from
the valve until it stops.
5.
Release the handle on the P&T valve - it should snap closed.
Close the faucet and turn on the cold water supply. As the tank fills, the air pocket will
develop. Repeat this procedure as often as needed to reduce the frequency of the weeping
P&T valve.
Maintenance
Do not allow the burner to burn with a yellow flame, or continue to operate the water
heater with an improper burner flame.
Periodically, inspect the water heater vent for soot. Soot is a sign of incomplete
combustion and must be corrected before operating the water heater. This is your visual
warning that the water heater is operating in an unsafe manner. If soot is present,
immediately shut the unit down and contact your dealer or a qualified service agency.
Periodically inspect the vent for obstructions. Do not terminate the vent on your water
heater inside of add-on rooms, screen porches or patios. Doing so will result in products of
combustion being vented into the rooms or occupied areas.
Draining and winterization:
WARNING
Do not place a valve between the pressure and temperature (P&T) valve and the tank.
Do not remove or plug the relief valve under any circumstances.
8-15
Содержание 2016 EAGLE HT
Страница 1: ...2016 EAGLE 0177622 2016 PRINTED ON RECYCLED PAPER Generations of family fun TOWABLES...
Страница 2: ......
Страница 4: ......
Страница 10: ...Table of Contents Eagle Travel Trailer Fifth Wheel THIS PAGE IS INTENTIONALLY BLANK VI...
Страница 26: ...JAYCO TOWABLE SECTION 1 WARRANTY SERVICE THIS PAGE LEFT INTENTIONALLY BLANK 1 16...
Страница 90: ...JAYCO TOWABLE SECTION 7 PROPANE SYSTEMS This page left intentionally blank 7 12...
Страница 128: ...JAYCO TOWABLE SECTION 9 HEATING COOLING THIS PAGE LEFT INTENTIONALLY BLANK 9 4...
Страница 142: ...JAYCO TOWABLE SECTION 12 INTERIOR THIS PAGE LEFT INTENTIONALLY BLANK 12 6...
Страница 148: ...JAYCO TOWABLE SECTION 13 EXTERIOR Fifth Wheels Sealant Diagram 13 6...
Страница 154: ...JAYCO TOWABLE SECTION 15 ADDITIONAL INFORMATION Service Date Work Performed Performed By Notes 15 2...
Страница 155: ...SECTION 15 ADDITIONAL INFORMATION JAYCO TOWABLE NOTES 15 3...
Страница 157: ...SECTION 15 ADDITIONAL INFORMATION JAYCO TOWABLE THIS PAGE LEFT INTENTIONALLY BLANK 15 5...