Walk Testing
A.
Apply power and allow 3 minutes for warming up and stabilizing.
B.
Adjust the vertical pattern angle per Fig.1 below.
C.
Walk slowly across the field of view (in opposite directions) and observe the LED – it lights whenever you enter or exit a
sensitive beam. Allow 5 seconds between each test for the unit to stabilize.
D.
After testing, the LED can be disabled to prevent unauthorized tracing of the coverage pattern. To disable the LED,
remove the jumper from the left and middle pins of the LED selector (ON) and place it across the middle and right pins
(OFF).
Lens Arrays
Specifications
Detector
Quad Element low noise Pyroelectric sensor
Operating Voltage
9 - 15V D.C.
Alarm Output
Normally closed dry contacts (0.5A/24V) with 15Ω resistor in series
Tamper Output
Normally closed dry contacts (0.5A/24V)
Alarm Period
2-3 seconds
Pulse Count
3 position selector 1, 2 and 4 pulse operation
Test LED
Walk test enabled and disabled with internal link
Coverage
110
∘
Range
Up to 12 meters
Operating Temperature
0 - 50
℃
PRM-S-LA5046