Walk Testing 

A.

 

Apply power and allow 3 minutes for warming up and stabilizing. 

B.

 

Adjust the vertical pattern angle per Fig.1 below. 

C.

 

Walk slowly across the field of view (in opposite directions) and observe the LED – it lights whenever you enter or exit a 
sensitive beam. Allow 5 seconds between each test for the unit to stabilize.   

D.

 

After testing, the LED can be disabled to prevent unauthorized tracing of the coverage pattern. To disable the LED, 
remove the jumper from the left and middle pins of the LED selector (ON) and place it across the middle and right pins 
(OFF).

 

 

 

Lens Arrays 

 

 

 

 

 

 

 

 

 

 

Specifications 

Detector 

 

 

 

Quad Element low noise Pyroelectric sensor   

Operating Voltage 

 

9 - 15V D.C. 

Alarm Output 

 

 

Normally closed dry contacts (0.5A/24V) with 15Ω resistor in series

 

Tamper Output   

 

Normally closed dry contacts (0.5A/24V) 

Alarm Period 

 

 

2-3 seconds 

Pulse Count 

 

 

3 position selector 1, 2 and 4 pulse operation 

Test LED   

 

 

Walk test enabled and disabled with internal link 

Coverage   

 

 

110

 

Range 

 

 

 

Up to 12 meters 

Operating Temperature  

0 - 50

 

 

 

 