Small structures
In applications requiring only
one unit, install the unit
anywhere along one end wall,
propelling the fog upward and
horizontally down the length of
the structure. If there is forced
ventilation, choose the intake
end of the structure. The best
location for automated controls
is behind the fan at an easily-
accessible level for monitoring.
Large structures
Equally space the units within the structure. Lower humidity and/or cooling
requirements can allow for greater distance between fans. Usually, the
maximum distance between fans should be 20’ from the side and 35’ from
the front. If the structure has forced ventilation, shift the fans closer to the
intake end. The fans should always be propelling their fog with the direction
of natural or forced air flow.
Direction of air flow →
POSITIONING
Controller location area
Direction of air flow →
10’
20’
35’