Doc. ref :
333130A-EN
2018/01/05
Page 31 / 44
DRAFT R revision5
Receiver
RSRD
: Error messages
10.2
Error messages are given by the indicator light (RED color on indicator light column) connected to
J3
-01-02 Terminals.
This indicator light blinks a specific number of times in the event of a receiver malfunction:
number of
blinking
Message
Solution
1
Error on MCUs: Miscellaneous electronic fault
2
Error on MCUs: RAM
3
Error on MCUs: ROM
4
Error on MCUs: Parameters
Check the configuration using dedicated software*
5
Error on MCUs: Link with MCU no2
6
Error on MCUs: EEPROM
7
Error on MCUs: LOW VOLTAGE
Check power supply
8
Error on MCUs: RADIO
9
Error on MCUs: Safety relay
Every
second
Wired emergency stop button activated (pressed)
Fast blinks
Error detected on wired emergency stop button
Repeat a complete emergency stop cycle to clear
the error.
If the error appears again, check the wiring and the
emergency stop button.
* The dedicated programming software is available on JAY Electronique website. The use of the programming software is
protected by a password, this password is only delivered to a skilled person “level 2” (a person who was trained by JAY
Electronique, and who is authorized to modify RSRD receiver parameters).