background image

WARRANTY: 

JAVAC warrants your PCS-2 to be free from defects of materials or workmanship for 

one year from the date of purchase.  JAVAC does not warrant any machine that has 

been subject to misuse, negligence, or accident, or has been repaired or altered by 

anyone other than JAVAC. The PCS-2 is designed and manufactured for intermittent 

operation. Use of the vacuum pump for longer than 2 hours at any time may void 

warranty.

 The manufacturer warrants the PCS-2 for a period of one year.  To keep this 

WARRANTY in force it is required that the unit is used with compatible refrigerants 

and the vacuum pump oil be changed regularly with the correct type and grade. 

Operating the unit outside its design parameters will void warranty. 

JAVAC’s liability is limited to machines

 returned to JAVAC, return transportation 

prepaid, not later than thirty (30) days after the warranty period expires, and which 

JAVAC judges to have malfunctioned because of defective materials or workmanship.

JAVAC’s liability is limited to, at its option,

 repairing or replacing the defective machine 

or part. 

 This WARRANTY is in lieu of all other warranties, express or implied, whether of 

MERCHANTABILITY or of FITNESS FOR A PARTICULAR PURPOSE or otherwise.  

All such other warranties are expressly disclaimed. JAVAC practices continuous 

product research and improvement. We reserve the right to change specifications and 

product design without notice. Such revisions do not entitle the buyer to corresponding 

changes, improvements, additions or replacements for previously purchased 

equipment.

 JAVAC shall have no liability in excess of the price paid to JAVAC for the machine 

plus return transportation charges prepaid.  JAVAC shall have no liability for any 

incidental or consequential damages.  All such liabilities are EXCLUDED. 

Содержание PCS-2

Страница 1: ...es CD Series JL Series JLT Series JAVAC PCS 2 and PCS 2A Automotive 110 240V 60 50Hz Operating Instructions PORTABLE CHARGE STATION READ THIS MANUAL BEFORE OPERATING THE MACHINE Quality System Quality Endorsed Company TM Lic QEC24519 SAI Gobal ...

Страница 2: ... to the presence of important operating safety and maintenance servicing instructions in this Manual As used in the Manual it is intended to draw your attention to critical items It is important to read this entire Manual and be familiar with its contents before using the machine Responsibility Only a Qualified Technician who has been properly trained and certified in the care and use of such equi...

Страница 3: ... Automotive Table of Contents Page No 1 0 SAFETY PRECAUTIONS 1 2 0 SPECIFICATIONS FEATURES AND WARRANTY 2 3 0 SET UP AND OPERATION 4 4 0 STORAGE AND MAINTENANCE 7 5 0 TROUBLESHOOTING 8 6 0 SERVICE 8 Service Return Refer to Back Cover ...

Страница 4: ... PROPER SAFETY AND HANDLING REQUIREMENTS for the Refrigerant being charged by reviewing the Material Safety Data Sheets MSDS and the Temperature Vapour Pressure information PERFORM LEAK DETECTION in accordance with recommended practice only For best results use only a refrigerant detector such as the JAVAC D TEK or TEK Mate NEVER USE OXYGEN for this process as it can become an explosive mixture in...

Страница 5: ...safe and easy transport x Fan cooled vacuum pump for greater reliability x Removable scale platform for use with larger diameter bottles x Removable scale head lead and platform for independent use x Integrated fuse and thermal protection in vacuum pump x Integrated hose carrier x Easy access to oil box on vacuum pump for speedy oil changes x Battery operated scale set Unit does not require mains ...

Страница 6: ... transportation prepaid not later than thirty 30 days after the warranty period expires and which JAVAC judges to have malfunctioned because of defective materials or workmanship JAVAC s liability is limited to at its option repairing or replacing the defective machine or part This WARRANTY is in lieu of all other warranties express or implied whether of MERCHANTABILITY or of FITNESS FOR A PARTICU...

Страница 7: ...tained close off desired valves and check refrigeration system for vacuum stability x Turn off vacuum pump Never switch off the vacuum pump before closing the vacuum valve on manifold first Doing so will result in vacuum pump oil being syphoned back into refrigeration system In the event of power failure or overload condition check vacuum pump for adequate oil quantity Fill if necessary Carefully ...

Страница 8: ...cale platform by depressing the locking button located near the pivot point of the handle right side of unit Pull handle forward while holding the scale platform Lower platform by hand so it sits horizontal See pictures below ...

Страница 9: ...ght and valves are closed x Evacuate air from lines using the vacuum pump x Close vacuum valve and open bottle tap x Open manifold charge valve s as desired to obtain correct charge amount Note As the scale is powered by a 9V battery located in the back of the controller mains power is not required for charging If power is not available for charging purposes the lines may be purged of air with ref...

Страница 10: ...e For best results store the unit in an environmentally controlled area when not in use x Always relieve any pressure in the hoses manifold before storage Do not place hoses manifold under vacuum for storage Doing so will result in the vacuum pump oil being syphoned from the pump MAINTENANCE x Your PCS 2 will provide many years of reliable service if it is properly maintained The actual maintenanc...

Страница 11: ... DO NOT CHANGE any of these components as the safety of the machine could be compromised All service work must be performed at a JAVAC approved facility in order to maintain the safety rating and the Warranty if applicable Technical assistance and service information can be obtained by contacting JAVAC UK 44 0 1642 232 880 Or the Organisation where you purchased your PCS 2 The vacuum pump oil used...

Отзывы: