OPERATING INSTRUCTION, FEATURES, AND CONTROLS

INTRODUCTION

This manual contains all of the information needed for the 
proper installation and operation of your Jason MicroSilk

®

 

Demonstration System. The demonstration system has been 
designed to give you years of relaxing trouble-free service, 
provided the unit is maintained and operated in accordance 
with these instructions.

Thoroughly clean and disinfect the unit as described in 
the CLEANING section of the USER MAINTENANCE 
INSTRUCTIONS section of this owner’s manual before its 
first use and periodically thereafter.
WARNING: Before operating, refer to the instructions at the 
end of this owner’s manual pertaining to the risk of fire, electric 
shock, or injury to persons.

GENERAL OPERATION INSTRUCTIONS

1. Use this unit only for its intended use as described in the 
manual.

2. To avoid injury, exercise care when entering or exiting the 
bath, the floor may be slippery.

3. Do not use the door as a support while entering or exiting 
the bath, as door may swing with applied weight.

4. Do not open the door until all water has been drained from 
the bath.

5.  Enter the bath and latch the door securely.  The downward 
motion of the door level locks and seals the door.

6. Be certain the tub drain is open as first water coming from 
the tub spout may be too cold or too hot.  Carefully test the 
water temperature by slowly moving hand into the water 
stream.

7.  After adjusting the water temperature, move the drain valve 
handle all the way to the left to close the tub drain.

CAUTION:

 Keep hair, towels, and clothing away from the 

suction fitting whenever the equipment is On. Never operate 
the equipment with the suction cover off, as doing so voids 
the manufacturer’s warranty. It is a safety cover designed to 
eliminate the potential of hair and body entrapment.

MICROSILK OPERATION

All Jason MicroSilk baths are pre-plumbed at the factory 
with standard equipment. Standard equipment includes a 
Microbubble generator unit, MicroSilk jet, and an air actuated 
On/Off switch.

CAUTION: NEVER RUN THE MICROSILK PUMP WITHOUT 
ENOUGH WATER IN THE BATH TO COVER THE JETS.

Air ON/OFF Button The Air On/Off button provides a safe 
and convenient method for controlling the MicroSilk bath. The 
Air On/Off button is factory mounted onto the bath prior to 
shipment. Fill the bath to at least two (2) inches above the jet 
and press the Air On/Off button to start or stop the MicroSilk 
unit. A timer will automatically stop the unit after 20 minutes of 
operation if it is not stopped manually.

MicroSilk Unit

The MicroSilk unit generates oxygen rich microbubbles that fill 
the bath. MicroSilk units provided on Jason baths are factory 
tested when assembled and again retested after installation 
on the bath.

MicroSilk Port

A strategically placed MicroSilk port is provided for complete 
enjoyment of the bath.

WHIRLPOOL OPERATION

All Jason Walk-In Whirlpool baths are pre-plumbed at the 
factory with standard equipment. Standard equipment includes 
directional hydrotherapy jets, and an air actuated On/Off switch.

CAUTION: NEVER RUN THE WHIRLPOOL PUMP WITHOUT 
ENOUGH WATER IN THE BATH TO COVER THE JETS.

Whirlpool Jets

Strategically placed whirlpool jets are provided for complete 
enjoyment of the bath. The jets are specially designed for 
maximum whirlpool action with direction and flow control. 
Changing the direction of the jets will concentrate the 
massaging jet stream to the area of preference and turning 
the flange of the jet will adjust the amount of flow.

Whirlpool Pump

The pump provided on Whirlpool baths is factory tested when 
assembled onto the bath. The pump is designed to incorporate 
high quality, long-life seals which provide superior service. 
However, should the pump need service, use the suction and 
discharge unions provided for easy removal.

Содержание Vivere Series

Страница 1: ...inspect the unit Failure of the carrier to respond should be reported to the seller and carrier Always file a freight claim promptly If the carton shows any sign of damage thoroughlyinspecttheproduct...

Страница 2: ...rictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physicia...

Страница 3: ...nts des antihistaminiques vasoconstricteurs vasodilatateurs les hypnotiques les narcotiques ou des tranquillisants F Personnesayantdesant c dentsdemaladiecardiaque d hypotensionoud hypertensionart rie...

Страница 4: ...cal and plumbing connections should be made by a qualified professional NOTE Failure to follow these pre installation proce dures could result in voiding the warranty The manu facturer will not be lia...

Страница 5: ...se the electrical service from the GFCI to the bath control should be direct and not interrupted by a switch Never use a switch in conjunction with a control device This will VOID THE MANUFACTURER S W...

Страница 6: ...nt Off and then drain the water The bath unit and its plumbing are designed to drain after each use whether used as a hydrotherapy bath or soaking bath EXTENSION PANEL INSTALLATION The Vivere Collecti...

Страница 7: ...er designed to eliminate the potential of hair and body entrapment MICROSILK OPERATION All Jason MicroSilk baths are pre plumbed at the factory with standard equipment Standard equipment includes a Mi...

Страница 8: ...per access to bath equipment 4 Make sure that all the plumbing and fixtures in the bathroom are in good working order and have no leaks 5 Do not use carpeting or other materials or furniture which can...

Страница 9: ...ing vents are not blocked clea and allow motor to cool down Check service wire size b Refer to Jason Customer Service Pump leaks at shaft a Damaged or defective shaft seal a Refer to Jason Customer Se...

Отзывы: