![JASON Hydrotherapy forma AirMasseur RC553PS Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/jason-hydrotherapy/forma-airmasseur-rc553ps/forma-airmasseur-rc553ps_owners-manual_3502430008.webp)
Jason International, Inc. •
501.771.4477
Page 8 of 15
Customer Service : 800.255.5766
Copyright © 2010 Jason International.
CONTROL BOx CONNECTIONS
INSTALLATION INSTRUCTIONS (cont.)
STANDARD EDITION AIRMASSEUR
®
PREMIER EDITION AIRMASSEUR
®
Jason’s Standard Edition AirMasseur
®
system features the
best in luxury bathing for the leisure bath industry. To assure
that your bath functions properly the blower control must be
properly connected.
Standard edition airmaSSeur
®
PartS LiSt
Blower
Blower Control Box
Keypad
Keypad Cable
Control Box Stand
Figure 10
Jason’s Premier Edition AirMasseur
®
system incorporates
all the features of the Standard Edition system and
includes the benefits of ozone sanitation system, and
an LED Chromatherapy light. To assure that your bath
functions properly, the blower control box must be properly
connected.
Premier
edition airmaSSeur
®
PartS LiSt
Blower
Blower Control Box
Control Box Stand
Ozone Sanitation Unit
Keypad
Keypad Cable
Figure 11
NOTe:
For
120v systems
, the power cord for the Blower
control box must be plugged into a 120v, 15 amp GFCI
dedicated circuit.
NOTe:
For
120v systems
, the power cord for the Blower
control box must be plugged into a 120v, 15 amp GFCI
dedicated circuit.
NOTe:
This diagram
(Figure 10)
also applies to 50 Hz,
240v controls, and power supply systems. Except that the
Blower junction box must be connected into one dedicated
240v, 15 Amp GFCI circuit.
NOTe:
This diagram
(Figure 11)
also applies to 50 Hz,
240v controls, and power supply systems. Except that the
Blower junction box must be connected into one dedicated
240v, 15 Amp GFCI circuit.
tHe BLoWer ControL BoX
The blower and keypad must be plugged into the proper
receptacles for correct operation of the AirMasseur® system.
See
Figure 10
for connections: (C) 8-pin mini-DIN terminal
for the AirMasseur® keypad. (A) The power cord for the
blower control box must be connected into the proper GFCI
dedicated circuit for the system (see note above). (B) Pre-
wired power cord to the blower.
tHe BLoWer ControL BoX
The blower and keypad must be plugged into the proper
receptacles for correct operation of the AirMasseur® system.
See Figure 11
for connections: (C) 8-pin mini-DIN terminal
for the AirMasseur® keypad. (A) The power cord for the
blower control box must be connected into the proper GFCI
dedicated circuit for the system (see note above). (B) Pre-
wired power cord to the blower. (E) Six-pin mini-DIN terminal
for LED light.