background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 8 of 18

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2011 Jason International.

INSTALLATION INSTRUCTIONS (cont.)

CLeANINg

Remove all loose debris. 

1. 

Construction plaster or excess 

grout  can  be  removed  with  the  use  of  a  wood  (edge) 
trowel.

Paint  or  tar  stains 

2. 

may  need  to  be  removed  with  a 

cleaner  such  as  paint  thinner,  turpentine,  or  isopropyl 
alcohol  (rubbing  alcohol).  Never  allow  the  cleaner  to 
soak against the acrylic surface for long periods of time. 

Always  rinse  the  surface  immediately

  following  the 

use of cleaners.

Follow  the  manufacturer’s  instructions  for  safe  use  of 

3. 

cleaning products. If the surface becomes scratched or 
dulled, it may be restored by using a quality plastic polish, 
like Novus Plastic Polish No. 2 (available from the Jason 
Dealer).

 It is always preferable to protect the acrylic 

surface during installation to minimize cleanup and 

prevent surface damage.

WATeR TeSTINg

Before  finishing  the  installation,  it  is  recommended  that  the 
bath be water tested and the plumbing tested for leaks. 

Before water testing the bath, make sure any pump unions 

1. 

are hand tight. Do not over tighten or use a pipe wrench. 
This will damage the unions and cause leaking. If the unit 
leaks with the unions hand tight, then loosen the unions(s) 
and check the O-ring seal to ensure it is properly seated. 

Fill  and  operate  the  bath.

2. 

  Close  the  drain  and  fill 

the  bath  with  water  to  at  least  10  inches  [25  cm] 
below  the  bath  deck.  The  inlet  temperature  should 
not  exceed  104°F  (40°C)  as  this  could  damage  the 
acrylic surface. Refer to the 

FILLING AND DRAINING

 

section  of  this  owner’s  manual  for  more  information. 

Inspect the plumbing for leaks.

3. 

 

Turn the equipment Off and then drain the water. 

4. 

The 

bath unit and its plumbing are designed to drain after each 
use whether used as a hydrotherapy bath, soaking bath, 
or when taking a shower.

Содержание forma AC553

Страница 1: ... responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered the carrier must be immediately notified in writing with a request for a representative to inspect the unit Failure of the carrier to respond should be reported to the seller and carrier Always file a freight claim promptly If the carton shows sign of damage inspect the product before accepting...

Страница 2: ...o the minimum recommended access panel size in Table 1 Specifications Table 1 Specifications 66 x 36 x 22 39 36 x 17 in 53 0 168 x 91 x 56 148 91 x 43 cm 259 72 x 36 x 22 49 36 x 17 in 55 3 183 x 91 x 56 185 91 x 43 cm 270 72 x 42 x 22 56 36 x 17 in 51 7 183 x 107 x 56 212 91 x 43 cm 252 66 x 36 x 22 44 36 x 17 in 56 3 168 x 91 x 56 167 91 x 43 cm 275 60 x 60 x 20 5 55 36 x 17 in 48 4 152 x 152 x ...

Страница 3: ... related plumbing If a Jason Double CascadeTM is provided please refer to the included instructions and install at this time 5 Remove the packing board before installing the bath The bath is equipped with separate bath equipment sup port bases which are joined for shipment with packing boards Detach the packing board from the bath and from underneath the equipment WARNING Anymodificationtotheequip...

Страница 4: ...form maintenance while system is running The Jason MicroSilk system has been factory assembled followingETLandIAPMOguidelines Forshippingpurposes the MicroSilk Pump Assembly is packaged separately and disconnected from the bath Note Verify the MicroSilk Pump Assembly is the same unit that was provided for the bath being installed The serialnumberlistedonthelabelprovidedontheMicroSilk Pump Assembly...

Страница 5: ...end is angled to allow for proper drainage Figure 6 6 Clamp the MicroSilk Suction Line to the MicroSilk Suction Barb using the clamp provided on the tubing Assure the MicroSilk Suction Line will allow proper drainage to the suction See Figure 8 The suction hose must have a continuous drop from the suction barb to the suction fitting Caution Confirm all tubing is fully engaged on its respective bar...

Страница 6: ...nsed plumber 4 Standard Premier Edition MicroSilk Whirlpool Control Box 120v The MicroSilk generator unit is shipped separate from the bath Follow the instructions for the MicroSilk Pump Assembly Field Installation in the Installation section of this owner s manual instructions are also packaged with the MicroSilk unit packaging The pump is prewired to the control box The control boxes have a 36 9...

Страница 7: ...tallation the control box bracket and controls must be positioned horizontally and located to permit access for inspection and servicing The MicroSilk pump s power cord will need to be plugged into the control box Connect the pump s male J J plug to the female J J plug of the control box s load line The MicroSilk and pump junction box must be plugged into a dedicated 240v 20A 50 or 60 Hz GFCI prot...

Страница 8: ... acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks Before water testing the bath make sure any pump unions 1 are hand tight Do not over tighten or use a pipe wrench This will damage the unions and cause leaking If the unit leaks with the...

Страница 9: ...es all the features of the Standard Edition system and includes the benefits of a combination pump heater ozone sanitation system and an LED Chromatherapy light To assure that your bath functions properly the pump control box must be properly connected NOTE For 120v systems the power cord for the Micro Silk control box must be plugged into a 120v 20 amp GFCIdedicatedcircuit ThepowercordfortheWhirl...

Страница 10: ...is manual for connecting the pump to the control box THE PUMP CONTROL BOX The Pump Keypad LED light Ozone Sanitation Unit Vac uum Switch and Water Level Temperature Sensor must be pluggedintotheproperreceptaclesforcorrectoperationofthe MicroSilk Whirlpool system See Figure 12 for connections A The junction box for the pump MicroSilk control boxes and heater must be connected into a 240v 20 amp GFC...

Страница 11: ...udes both a Microbubble generator unit and a whirlpool bath system The whirlpool bath system includes a quiet 1 1 2 HP 3 speed pump Automatic 1 5kW Heater Chromatherapy mood light Automatic Ozone System that will be operated any time the pump is powered a digital control with LCD display window low water and temperature sensors flow and pressure sensors to ensure proper pump operation and a 20 min...

Страница 12: ...will keep the system running properly Never operate the system without the pre filter internal filter screen and suction cover installed OPERATING INSTRUCTIONS FEATURES AND CONTROLS cont Filling and Draining Close the drain and fill the bath with water at least two 2 inches 50mm above the jets The inlet temperature should not exceed 40 C 104 F as this could damage the acrylic surface When bath is ...

Страница 13: ...ol icon is used to activate the whirlpool pump and the 20 minute timer Pressing the icon the first time starts the pump Pressing the icon again will shut the pump off MicroSilk On Off Icon The MicroSilk icon is used to activate the MicroSilk pump and the 20 minute timer Pressing the icon the first time starts the pump Pressing the icon again will shut the pump off m MICROSILK wHIRLPOOL LED Light W...

Страница 14: ...yed for 5 seconds if no water is detected Vacuum Error is displayed if the MicroSilk suction is blocked LED Light Icon Hold the key for less than two 2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds to change modes The Light icon should remain lit as long as the bath is connected to a power supply This function has a two hour timer and remembers the last mode The LCD...

Страница 15: ...installed is well vented and allows enough ventilation and air circulation to dry the bathroom environment within a short time after taking a bath or shower 2 If your bath or shower unit is tiled in use units with an integral tile flange or make sure a tile flange kit or a similar mechanical barrier is installed to prevent shower spray splash or overflow to leak behind the bathtub 3 Make sure the ...

Страница 16: ...er b Refer to installer dealer Pump operates but water is not being pumped a Suction or discharge blocked b Suction air leak System usually surges a Remove obstruction b Make sure connection is tight on suction side of the pump Pump does not manually shut off a Digital or Touch Control defective a Refer to installer dealer Pump shuts off by itself or before set time elapses a Internal filter restr...

Страница 17: ...eated and thermal protection device deactivated motor Possibly low voltage b GFCI tripped c Water fell below recommended level a Make sure motor air cooling vents are not blocked Clear and allow motor to cool down Check service wire size b Refer to installer dealer c Fill to recommended level 2 above jets Pump does not turn off after set time elapses a Wiring error or control problem a Refer to in...

Страница 18: ...soconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Persons using medication should consult a physician before using a therapy bath since some medication may induce drowsiness while other medication may affect hea...

Отзывы: