background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 10 of 18

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2011 Jason International.

SIgNATURe eDITION MICROSILK-WhIRLPOOL 

PARTS LIST

MicroSilk Pump Unit 

MicroSilk Control Box

Pump    

 

Pump Control Box

Keypad  

 

Keypad Cable   

Control Box Stand  

Water Level/Temp Sensor

LED Light Assembly  

LED Light Cable

Vacuum Sensor  

Ozone Sanitation Unit 

Heater

Jason’s Signature Edition MicroSilk-Whirlpool system is the 

most advanced bath manufactured by Jason International, 

Inc. and features the ultimate in luxury bathing for the leisure 

bath industry. The MicroSilk and pump control boxes must 

be properly connected for the bath to function correctly.

INITALIZATION OF SIgNATURe eDITION CONTROL 

SySTeM

The pump and MicroSilk junction box must be connected to 

its dedicated service prior to filling the bath with water.

 This 

will assure the control box is properly initialized.

The MIRCROSILK CONTROL bOX

The MicroSilk unit must be plugged into the proper receptacle 

for correct operation of the MicroSilk-Whirlpool system. See 

Figure 12

 for connections: (I) The MicroSilk pump’s power 

cord will need to be plugged into the control box (H).  Refer 

to the 

ELECTRICAL 

section of this manual for connecting 

the pump to the control box.

The PUMP CONTROL bOX

The Pump, Keypad, LED light, Ozone Sanitation Unit, Vac-

uum Switch, and Water Level/Temperature Sensor must be 

plugged into the proper receptacles for correct operation of the 

MicroSilk-Whirlpool system. See 

Figure 12

 for connections: 

(A) The junction box for the pump/MicroSilk control boxes 

and heater must be connected into a 240v, 20 amp GFCI 

dedicated circuit. (B) Pre-wired power cords to pump (C) and 

ozone unit (G). Eight-pin mini-DIN terminal for installation of 

Air-Whirlpool keypad (F). Six-pin mini-DIN terminals for the 

water/temperature sensor (D), and LED light (E) to the pump 

control box. (J) Two-pin terminal for installation of the vacuum 

switch to the water/temperature sensor.

SIgNATURe eDITION MICROSILK

TM

-WhIRLPOOL

PReMIeR eDITION MICROSILK-WhIRLPOOL  

PARTS LIST

MicroSilk Pump Unit 

MicroSilk Control Box 

Pump    

 

Pump Control Box

Control Box Stand  

Water Level/Vacuum Sensor 

Keypad  

 

Keypad Cable   

 

LED Light Assembly 

LED Light Cable 

Ozone Sanitation Unit

Figure 11

CONTROL bOX CONNeCTIONS (cont.)

NOTE: This diagram (Figure 11) also applies to 50 hz, 

240v pumps, controls, and power supply systems. Ex-

cept  that  the  MicroSilk  and  Whirlpool  pump  junction 

boxes must be connected into one dedicated 240v, 20 

Amp GFCI circuit.

NOTE: This diagram (Figure 12) also applies to 50 hz, 

240v pumps, controls, and power supply systems.

Figure 12

Содержание forma AC553

Страница 1: ... responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered the carrier must be immediately notified in writing with a request for a representative to inspect the unit Failure of the carrier to respond should be reported to the seller and carrier Always file a freight claim promptly If the carton shows sign of damage inspect the product before accepting...

Страница 2: ...o the minimum recommended access panel size in Table 1 Specifications Table 1 Specifications 66 x 36 x 22 39 36 x 17 in 53 0 168 x 91 x 56 148 91 x 43 cm 259 72 x 36 x 22 49 36 x 17 in 55 3 183 x 91 x 56 185 91 x 43 cm 270 72 x 42 x 22 56 36 x 17 in 51 7 183 x 107 x 56 212 91 x 43 cm 252 66 x 36 x 22 44 36 x 17 in 56 3 168 x 91 x 56 167 91 x 43 cm 275 60 x 60 x 20 5 55 36 x 17 in 48 4 152 x 152 x ...

Страница 3: ... related plumbing If a Jason Double CascadeTM is provided please refer to the included instructions and install at this time 5 Remove the packing board before installing the bath The bath is equipped with separate bath equipment sup port bases which are joined for shipment with packing boards Detach the packing board from the bath and from underneath the equipment WARNING Anymodificationtotheequip...

Страница 4: ...form maintenance while system is running The Jason MicroSilk system has been factory assembled followingETLandIAPMOguidelines Forshippingpurposes the MicroSilk Pump Assembly is packaged separately and disconnected from the bath Note Verify the MicroSilk Pump Assembly is the same unit that was provided for the bath being installed The serialnumberlistedonthelabelprovidedontheMicroSilk Pump Assembly...

Страница 5: ...end is angled to allow for proper drainage Figure 6 6 Clamp the MicroSilk Suction Line to the MicroSilk Suction Barb using the clamp provided on the tubing Assure the MicroSilk Suction Line will allow proper drainage to the suction See Figure 8 The suction hose must have a continuous drop from the suction barb to the suction fitting Caution Confirm all tubing is fully engaged on its respective bar...

Страница 6: ...nsed plumber 4 Standard Premier Edition MicroSilk Whirlpool Control Box 120v The MicroSilk generator unit is shipped separate from the bath Follow the instructions for the MicroSilk Pump Assembly Field Installation in the Installation section of this owner s manual instructions are also packaged with the MicroSilk unit packaging The pump is prewired to the control box The control boxes have a 36 9...

Страница 7: ...tallation the control box bracket and controls must be positioned horizontally and located to permit access for inspection and servicing The MicroSilk pump s power cord will need to be plugged into the control box Connect the pump s male J J plug to the female J J plug of the control box s load line The MicroSilk and pump junction box must be plugged into a dedicated 240v 20A 50 or 60 Hz GFCI prot...

Страница 8: ... acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks Before water testing the bath make sure any pump unions 1 are hand tight Do not over tighten or use a pipe wrench This will damage the unions and cause leaking If the unit leaks with the...

Страница 9: ...es all the features of the Standard Edition system and includes the benefits of a combination pump heater ozone sanitation system and an LED Chromatherapy light To assure that your bath functions properly the pump control box must be properly connected NOTE For 120v systems the power cord for the Micro Silk control box must be plugged into a 120v 20 amp GFCIdedicatedcircuit ThepowercordfortheWhirl...

Страница 10: ...is manual for connecting the pump to the control box THE PUMP CONTROL BOX The Pump Keypad LED light Ozone Sanitation Unit Vac uum Switch and Water Level Temperature Sensor must be pluggedintotheproperreceptaclesforcorrectoperationofthe MicroSilk Whirlpool system See Figure 12 for connections A The junction box for the pump MicroSilk control boxes and heater must be connected into a 240v 20 amp GFC...

Страница 11: ...udes both a Microbubble generator unit and a whirlpool bath system The whirlpool bath system includes a quiet 1 1 2 HP 3 speed pump Automatic 1 5kW Heater Chromatherapy mood light Automatic Ozone System that will be operated any time the pump is powered a digital control with LCD display window low water and temperature sensors flow and pressure sensors to ensure proper pump operation and a 20 min...

Страница 12: ...will keep the system running properly Never operate the system without the pre filter internal filter screen and suction cover installed OPERATING INSTRUCTIONS FEATURES AND CONTROLS cont Filling and Draining Close the drain and fill the bath with water at least two 2 inches 50mm above the jets The inlet temperature should not exceed 40 C 104 F as this could damage the acrylic surface When bath is ...

Страница 13: ...ol icon is used to activate the whirlpool pump and the 20 minute timer Pressing the icon the first time starts the pump Pressing the icon again will shut the pump off MicroSilk On Off Icon The MicroSilk icon is used to activate the MicroSilk pump and the 20 minute timer Pressing the icon the first time starts the pump Pressing the icon again will shut the pump off m MICROSILK wHIRLPOOL LED Light W...

Страница 14: ...yed for 5 seconds if no water is detected Vacuum Error is displayed if the MicroSilk suction is blocked LED Light Icon Hold the key for less than two 2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds to change modes The Light icon should remain lit as long as the bath is connected to a power supply This function has a two hour timer and remembers the last mode The LCD...

Страница 15: ...installed is well vented and allows enough ventilation and air circulation to dry the bathroom environment within a short time after taking a bath or shower 2 If your bath or shower unit is tiled in use units with an integral tile flange or make sure a tile flange kit or a similar mechanical barrier is installed to prevent shower spray splash or overflow to leak behind the bathtub 3 Make sure the ...

Страница 16: ...er b Refer to installer dealer Pump operates but water is not being pumped a Suction or discharge blocked b Suction air leak System usually surges a Remove obstruction b Make sure connection is tight on suction side of the pump Pump does not manually shut off a Digital or Touch Control defective a Refer to installer dealer Pump shuts off by itself or before set time elapses a Internal filter restr...

Страница 17: ...eated and thermal protection device deactivated motor Possibly low voltage b GFCI tripped c Water fell below recommended level a Make sure motor air cooling vents are not blocked Clear and allow motor to cool down Check service wire size b Refer to installer dealer c Fill to recommended level 2 above jets Pump does not turn off after set time elapses a Wiring error or control problem a Refer to in...

Страница 18: ...soconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Persons using medication should consult a physician before using a therapy bath since some medication may induce drowsiness while other medication may affect hea...

Отзывы: