background image

Jason International, Inc.  

·

  501.771.4477                              Page 4 of 12                                              Customer Service: 800.255.5766 

Copyright © 2021 Jason International, Inc. 

Cautionary Warnings (English/French)

 

 
CAUTION: Ambient temperature under the bath where 
equipment is installed must not exceed 122°F (50°C). 
 
WARNING: Any modification to the equipment is not 
recommended and will void the 

Manufacturer’s 

warranty. 
 
DANGER - RISK OF ELECTRIC SHOCK: 

Connect only to 

a circuit protected by a Ground Fault Circuit Interrupter 
(GFCI). In the unlikely occurrence of a current imbalance 
in the power conductors, the GFCI will interrupt the power 
to the bath. 
 

WARNING: The electrical service to the GFCI must not 
be interrupted by any control device. Likewise, the 
electrical service from the GFCI to the bath control 
should be direct and not interrupted by a switch. 
Never use a switch in conjunction with a control 
device. 
This will VOID THE MANUFACTURER’S WARRANTY. 
 
DANGER - Do not alter the factory installed wiring. All 
building materials and wiring should be routed away 
from the equipment or other heat-producing 
components of the unit. 
 
CAUTION: 

Keep hair, towels, and clothing away from the 

suction fitting whenever the equipment is On. Never 
operate the equipment with the suction cover off, doing so 
voids the manufacturer’s warranty--it is a safety cover 
designed to eliminate the potential of hair and body 
entrapment. 

 
WARNING: Before operating refer to the instructions 
at the end of this owner’s manual pertaining to the risk 
of fire, electric shock, or injury to persons. 
 
 
WARNING: Avoid high humidity levels in your home. 
Mold, mildew, fungi and bacteria which may be 
harmful to health thrive in areas with continued high 
humidity levels; therefore, every precaution should be 
taken to make sure your plumbing fixtures including 
bathtubs, therapy baths, or showers do not become a 
source of high humidity due to improper installations 
or leaks. 
 
 
WARNING: Always turn off power at the main 
electrical service panel when servicing the bath 

 

 
CAUTION: Risk of Electric Shock 

- -Two disconnect 

switches are required to de-energize the unit before 
servicing.  [For baths requiring two circuits] 
 

 
CAUTION: Not Suitable for Field-Installed Heater

 

 

 

ATTENTION: la temperature ambiante sous la baignoire 
où l'équipement est installé ne doit pas dépasser 50°C. 

 
AVERTISSEMENT : Toute modification de l'équipement 
n’est pas recommandé et annulera la garantie du 
fabricant. 

 

DANGER - RISQUE DE CHOC ÉLECTRIQUE

 : Connecter 

uniquement à un circuit protégé par un disjoncteur (GFCI). 
Dans l’éventualité peu probable d'un déséquilibre de courant, 
le GFCI coupera le courant du bain. 
 

 

AVERTISSEMENT : Le service électrique au GFCI ne doit 
pas être interrompu par un dispositif de contrôle. De 
même, le service électrique du GFCI au contrôle de bain 
doit être direct et ininterrompu par un controlleur. Ne 
jamais utiliser un commutateur en conjonction avec un 
dispositif de commande. 
Cela annulera la garantie du fabricant. 
 
DANGER - Ne pas modifier le câblage installé en usine. 
Tous les matériaux de construction et câblage doivent 
être éloignés de toutes sources de chaleur moduites par 
le abin. 

 

ATTENTION :

 Garder les cheveux, les serviettes et les 

vêtements à distance du raccord d'aspiration lorsque 
l'appareil est allumé. Ne jamais faire fonctionner l'équipement 
avec l'aspiration couvrir off, cela annule la garantie - c'est un 
dispositif de sécurité conçu à éviter l'occulusion du corps et 
des cheveux.

 

 
AVERTISSEMENT: Avant d'opérer le bain consulter les 
instructions à la fin de ce manuel concernant les risques 
d’incendie, de choc électrique ou de blessure ce 
propriétaire. 
 
AVERTISSEMENT: Évitez les hauts niveaux d'humidité 
dans votre maison. Les Moisissures, champignons et 
certaines bactéries peuvent être nocifs pour la santé et 
se développer dans ces zones; par conséquent, toutes 
les précautions doivent être prises pour vous assurer 
que votre plomberie, y compris les baignoires, bains 
thérapeutiques, ou les douches ne deviennent pas une 
source de forte humidité due à une mauvaise installation 
ou de fuites. 
 
AVERTISSEMENT: Toujours couper l'alimentation 
électrique au panneau de service électrique avant la 
maintenance. 
 
ATTENTION :

 

Risque de choc électrique - Deux interrupteurs 

de déconnexion sont nécessaires pour mettre l'unité hors 
tension avant l'entretien. [Pour les bains nécessitant deux 
circuits] 
 

ATTENTION:

 

Ne convient pas aux appareils de chauffage 

installés sur le terrain

 

Содержание Excel

Страница 1: ...o installation Damage to the unit during installation will not be covered by warranty and is the responsibility of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE MUST BE MADE PRIOR TO INSTALLATION Inspect plumbing and bath surface for missing or damaged components Alert your dealer of any discrepancies To protect the unit from damage keep the bath in the carton until ready for install...

Страница 2: ...hol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Lower water temperatures are recommended for extended use exceeding 10 15 minutes and for young children G Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should limit therapy bat...

Страница 3: ...10 15 minutes et pour les jeunes enfants F Puisque les températures excessives ont un potentiel élevé pour les fœtus durant les premiers mois de la grossesse les femmes enceintes ou possiblement enceintes doivent limiter la température de l eau de bain de traitement à 38 C G Personnes ayant des antécédents de maladie cardiaque d hypotension ou d hypertension artérielle de troubles circulatoires ou...

Страница 4: ...aths requiring two circuits CAUTION Not Suitable for Field Installed Heater ATTENTION la temperature ambiante sous la baignoire où l équipement est installé ne doit pas dépasser 50 C AVERTISSEMENT Toute modification de l équipement n est pas recommandé et annulera la garantie du fabricant DANGER RISQUE DE CHOC ÉLECTRIQUE Connecter uniquement à un circuit protégé par un disjoncteur GFCI Dans l éven...

Страница 5: ...ther used as a hydrotherapy bath soaking bath or just taking a shower NOTE If the unit fails to operate check the breaker panel to ensure that the circuit breaker is on Check the GFCI by testing and resetting it If the unit still fails to operate refer to the Trouble Shooting Guide section of this manual If the unit still fails to operate and is out of warranty contact an authorized service techni...

Страница 6: ...ollowing procedures should be followed Note Do no remote mount the blower more than 15 feet 4 5m away from the air inlet of the bath Choose a location as close as possible to the bath to ensure maximum efficiency 1 The installer must determine the layout of the piping exact remote mount location and service access before beginning any work Use 1 5 ABS or PVC plastic tubing Locate the blower in an ...

Страница 7: ...ughly after cleaning SURFACE MAINTENANCE Area with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e Novus Plastic Polish No 2 available at your Jason dealer followed by an application of acrylic paste wax Buff the surface with a clean soft cloth Do not use sandpaper steel wool or abrasive rubbing compounds If scratches are too deep to rub out o...

Страница 8: ...mum of 72 F 22 C 3 Drain and Overflow Install the drain and overflow assembly to the bath shell according to the instructions provided with the drain and position the bath in the area of intended installation Finish plumbing rough in of drain and overflow assembly At this time considerations should be made for the position and mounting of the faucet set as well as all related plumbing 4 Level Inst...

Страница 9: ...ace of this bath has been provided with a protective film which helps protect the bath during shipment and installation If the bath is tiled in remove the necessary portion of the film when installing the tile Additional protection may also be required to protect the acrylic surface during installation Protect the acrylic bath surface from damage during installation with a suitable material i e ca...

Страница 10: ... and not interrupted by a switch Never use a switch in conjunction with a control device This will VOID THE MANUFACTURER S WARRANTY The pumps are supplied with an electrical bonding lug to allow connection of a solid copper bonding conductor between the unit and other electrical equipment and exposed metal in the area as may be required by local code Note The air blower s exterior housing is made ...

Страница 11: ... If no voltage control is defective b Motor is not plugged into control box b Make sure plug is fully inserted into the control box outlet c Air switch Plastic air tubing disconnected or broken c Check and reconnect if necessary Equipment does not manually shut off a Control defective a Refer to installer dealer Equipment shuts off by itself or before set time elapses a Motor overheated and therma...

Страница 12: ...ent of equipment shall be F O B point of shipment This warranty shall not apply to any merchandise which has been subject to accident alteration abuse misuse abrasives corrosion and or electrolysis improper voltage supply misapplication careless handling improper installation maintenance abnormal chemical conditions nor does this warranty cover stains discoloration or the fading of color due to im...

Отзывы: