Controls
4
Front view
1.
Overheating LED to indicate overheating.
2.
Power LED to indicate the power is on.
3.
Downslope time control: 1~10s.
4.
Post-flow time control: 1~10s.
5.
"+" output terminal: To connect the work clamp.
6.
"-" output terminal: To connect the TIG torch.
7.
Torch switch plug connection.
8.
Gas terminal: To connect the gas hose of the TIG torch.
9.
2T/4T switch: When the toggle switch is switched to 4T, self-lock function is
available.
10. MMA/TIG selector switch.
11. Welding current adjustment knob.
12. Handle
Rear view
13
Power switch
14
Warning label
15
Input cable gland
16
Cooling fan
17
Gas inlet
7
Содержание TIG180
Страница 14: ...Electrical schematic 7 13...