Jasic Plasma Cut 100 Скачать руководство пользователя страница 6

RF Declaration

Equipment  that  complies  with  directive  2004/108/EC 
concerning  electromagnetic  compatibility  (EMC)  and  the 
technical requirements of EN60974-10 is designed for use in 
industrial  buildings  and  not  those  for  domestic  use  where 
electricity is provided via the low voltage public distribution 
system.  Di

culties  may  arise  in  assuring  class  A 

electromagnetic  compatibility  for  systems  installed  in 
domestic  locations  due  to  conducted  and  radiated 
emissions.

In  the  case  of  electromagnetic  problems,  it  is  the 
responsibility  of  the  user  to  resolve  the  situation.  It  may  be 
necessary to shield the equipment and fit suitable filters on 
the mains supply.

LF Declaration

Consult  the  data  plate  on  the  equipment  for  the  power 
supply requirements.

Due to the elevated absorbance of the primary current from 
the  power  supply  network,  high  power  systems  a

ect  the 

quality  of  power  provided  by  the  network.  Consequently, 
connection  restrictions  or  maximum  impedance 
requirements permitted by the network at the public network 
connection point must be applied to these systems.

In  this  case  the  installer  or  the  user  is  responsible  for 
ensuring  the  equipment  can  be  connected,  consulting  the 
electricity provider if necessary.

Materials and their disposal

The equipment is manufactured with materials, which do not 
contain  any  toxic  or  poisonous  materials  dangerous  to  the 
operator.

When  the  equipment  is  scrapped,  it  should  be  dismantled 
separating components according to the type of materials.

Do  not  dispose  of  the  equipment  with  normal  waste.  The 
European  Directive  2002/96/EC  on  Waste  Electrical  and 
Electronic  Equipment  states  the  electrical  equipment  that 
has reached its end of life must be collected separately and 
returned to an environmentally compatible recycling facility. 

Handling of Compressed gas cylinders and 
regulators

All  cylinders  and  pressure  regulators  used  in  welding 
operations should be handled with care.

Never  allow  the  electrode,  electrode  holder  or  any  other 
electrically “hot” parts to touch a cylinder.

Keep your head and face away from the cylinder valve outlet 
when opening the cylinder valve.

Always secure the cylinder safely

Never deface or alter any cylinder

4

Содержание Plasma Cut 100

Страница 1: ...00 100A 60 Power Factor 0 93 Class IP21S F Accessories Optional Items Part Number Description List Price 14 00 00203001 Earth Clamp and 3m Cable 19 00 14 00 01576000 P150 LT 6MTTorch 390 00 14 00 0200...

Страница 2: ...Operator Manual www jasic co uk Plasma Cut Series Plasma Cut 60 JP 60 Plasma Cut 80 JP 80 Plasma Cut 100 JP 100...

Страница 3: ...pplier of equipment in the UK and our products are supported by our extensive service network Call your distributor in the unlikely event of a problem occurring Please record below the details from yo...

Страница 4: ...e protection Insulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work ground Never touch the electrode if you are in contact...

Страница 5: ...fan may cut fingers and hands and snag garments Protections and coverings may be removed for maintenance and controls only by qualified personnel after first disconnecting the power supply cable Repl...

Страница 6: ...etwork at the public network connection point must be applied to these systems In this case the installer or the user is responsible for ensuring the equipment can be connected consulting the electric...

Страница 7: ...kly It has an easy to ignite arc and post flow function is available It has a wide range of uses especially for cutting stainless steel copper cast iron and aluminium etc With simple operation and hig...

Страница 8: ...Rated input capacity KVA 7 12 14 3 Rated input current A 15 22 21 7 Cutting current range A 20 60 20 80 20 100 No load voltage V 290 290 315 Duty cycle Imax 40 40 40 60 Efficiency 85 85 90 Power fact...

Страница 9: ...Controls 4 PANEL LAYOUT FRONT REAR 7 1 2 3 4 5 6 7 1 CONTROL PANEL 5 FAN 2 WORK RETURN SOCKET 6 MAINS SWITCH 3 TORCH CONNECTION SOCKET 7 MAINS CABLE 4 AIR REGULATOR...

Страница 10: ...R 2 2T 4T AUTOMATIC OPERATION 5 OVER TEMPERATURE ALARM 3 PURGE RUN SWITCH 6 MAINS INDICATOR 1 DIGITAL METER 4 CURRENT ADJUSTMENT 2 2T 4T AUTOMATION 5 ALARM INDICATOR 3 PURGE RUN SWITCH 6 MAINS INDICAT...

Страница 11: ...tails of the machine requirements can be found on the data plate of the machine or in the technical parameters shown in the manual The equipment should be connected by a suitably qualified competent p...

Страница 12: ...tting torch for its standard configuration The plasma cutters CUT60 and Cut 80 use the PT100 plasma cutting torch for its standard configuration The frequency of replacing the wearing parts of the cut...

Страница 13: ...A 1 6 60026 Gas Distributor 80 120A 1 7 51245 09 Tip Contact Cutting 0 9mm 30 40A Back Striking 10 8 51246 10 Tip Cutting 1 0mm 40 50A Back Striking 10 51246 11 Tip Cutting 1 1mm 50 60A Back Striking...

Страница 14: ...ng 1 9 62 32 09706 Handle c w Micro Switch Hand Torch 1 33 07301 20 Switch 1 14 75 34 C3055623 Handle Machine Torch 1 32 77 35 C3045012 Wrench for Electrode 1 6 23 36 C970 6mt Cable Assy Hand Torch 1...

Страница 15: ...or cutting operation 1 Do not touch the hot workpiece with bare hands to avoid burning 2 It is recommended not to ignite the arc in the air if not necessary for it will shorten the lifespan of the ele...

Страница 16: ...od ventilation This cutting machine can create powerful cutting current and has strict cooling requirements that cannot be met with natural ventilation Therefore the built in fan is very important in...

Страница 17: ...is on intake grills main voltage transformer inductance IGBT modules the fast recover diode and PCB etc Take care when blowing electronic components and do not dislodge any wiring connections Check th...

Страница 18: ...Parts List 8 Cut 60 80 16...

Страница 19: ...6932 Left plastic 26 10043995 EMC board 9 10049887 Base plate 27 10049741 rectifier bridge wires 10 10046933 Right plastic 28 10052876 Control board 11 10028470 Gas connector 29 10046896 Handle 12 100...

Страница 20: ...port 6 10004637 Quick connector 21 10043995 EMC board 7 10004622 Torch connector 22 10049050 Power transfer board 8 10006525 AC contactor 23 10049048 Arc starting control board 9 10035516 Reactor 24 1...

Страница 21: ...CUT 60 80 100 AIR PLASMA CUTTING MACHINE Order codes JP 60 JP 80 JP 100 Wilkinson Star Limited Issue 1 June 2015 Product is subject to change without notice xix...