background image

Safety Precautions

1

These general safety norms cover both arc welding 
machines and plasma cutting machines unless 
otherwise noted.

The  equipment  must  only  be  used  for  the  purpose  it  was 
designed  for.  Using  it  in  any  other  way  could  result  in 
damage or injury and in breach of the safety rules.

Only suitably trained and competent persons should use the 
equipment.  Operators  should    respect  the  safety  of  other 
persons.

Prevention against electric shock

The equipment should be installed by a qualified person and 
in  accordance  with  current  standards  in  operation.It  is  the 
users  responsibility  to  ensure  that  the  equipment  is 
connected  to  a  suitable  power  supply.  Consult  with  your 
utility supplier if required

If  earth  grounding  of  the  work  piece  is  required,  ground  it 
directly with a separate cable. 

Do not use the equipment with the covers removed.

Do  not  touch  live  electrical  parts  or  parts  which  are 
electrically charged. 

Turn o

 all equipment when not in use. 

Cables  (both  primary  supply  and  welding)  should  be 
regularly  checked  for  damage  and  overheating.  Do  not  use 
worn, damaged, under sized, or poorly jointed cables.

Ensure that you wear the correct protective clothing, gloves, 
head and eye protection. 

Insulate yourself from work and ground using dry insulating 
mats or covers big enough to prevent any physical contact 
with the work ground. 

Never touch the electrode if you are in contact with the work 
ground, or another electrode from a di

erent machine. 

Do not wrap cables over your body. 

Ensure that you take additional safety precautions when you 
are  welding  in  electrically  hazardous  conditions  such  as 
damp  environments,  wearing  wet  clothing,  and  metal 
structures.  Try  to  avoid  welding  in  cramped  or  restricted 
positions. 

Ensure  that  the  equipment  is  well  maintained.  Repair  or 
replace damaged or   defective parts immediately. Carry out 
any  regular  maintenance  in  accordance  with  the 
manufacturers instructions.

Safety against fumes and welding gases

Locate the equipment in a well-ventilated position.

Keep your head out of the fumes. Do not breathe the fumes. 

Ensure the welding zone is in a well-ventilated area. If this is 
not  possible  provision  should  be  made  for  suitable  fume 
extraction. 

If ventilation is poor, wear an approved respirator. 

Read  and  understand  the  Material  Safety  Data  Sheets 
(MSDS’s)  and  the  manufacturer’s  instructions  for  metals, 
consumable, coatings, cleaners, and de-greasers. 

Do not weld in locations near any de-greasing, cleaning, or 
spraying operations.  Be aware that heat and rays of the arc 
can  react  with  vapours  to  form  highly  toxic  and  irritating 
gases. 

2

Содержание Plasma Cut 100

Страница 1: ...00 100A 60 Power Factor 0 93 Class IP21S F Accessories Optional Items Part Number Description List Price 14 00 00203001 Earth Clamp and 3m Cable 19 00 14 00 01576000 P150 LT 6MTTorch 390 00 14 00 0200...

Страница 2: ...Operator Manual www jasic co uk Plasma Cut Series Plasma Cut 60 JP 60 Plasma Cut 80 JP 80 Plasma Cut 100 JP 100...

Страница 3: ...pplier of equipment in the UK and our products are supported by our extensive service network Call your distributor in the unlikely event of a problem occurring Please record below the details from yo...

Страница 4: ...e protection Insulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work ground Never touch the electrode if you are in contact...

Страница 5: ...fan may cut fingers and hands and snag garments Protections and coverings may be removed for maintenance and controls only by qualified personnel after first disconnecting the power supply cable Repl...

Страница 6: ...etwork at the public network connection point must be applied to these systems In this case the installer or the user is responsible for ensuring the equipment can be connected consulting the electric...

Страница 7: ...kly It has an easy to ignite arc and post flow function is available It has a wide range of uses especially for cutting stainless steel copper cast iron and aluminium etc With simple operation and hig...

Страница 8: ...Rated input capacity KVA 7 12 14 3 Rated input current A 15 22 21 7 Cutting current range A 20 60 20 80 20 100 No load voltage V 290 290 315 Duty cycle Imax 40 40 40 60 Efficiency 85 85 90 Power fact...

Страница 9: ...Controls 4 PANEL LAYOUT FRONT REAR 7 1 2 3 4 5 6 7 1 CONTROL PANEL 5 FAN 2 WORK RETURN SOCKET 6 MAINS SWITCH 3 TORCH CONNECTION SOCKET 7 MAINS CABLE 4 AIR REGULATOR...

Страница 10: ...R 2 2T 4T AUTOMATIC OPERATION 5 OVER TEMPERATURE ALARM 3 PURGE RUN SWITCH 6 MAINS INDICATOR 1 DIGITAL METER 4 CURRENT ADJUSTMENT 2 2T 4T AUTOMATION 5 ALARM INDICATOR 3 PURGE RUN SWITCH 6 MAINS INDICAT...

Страница 11: ...tails of the machine requirements can be found on the data plate of the machine or in the technical parameters shown in the manual The equipment should be connected by a suitably qualified competent p...

Страница 12: ...tting torch for its standard configuration The plasma cutters CUT60 and Cut 80 use the PT100 plasma cutting torch for its standard configuration The frequency of replacing the wearing parts of the cut...

Страница 13: ...A 1 6 60026 Gas Distributor 80 120A 1 7 51245 09 Tip Contact Cutting 0 9mm 30 40A Back Striking 10 8 51246 10 Tip Cutting 1 0mm 40 50A Back Striking 10 51246 11 Tip Cutting 1 1mm 50 60A Back Striking...

Страница 14: ...ng 1 9 62 32 09706 Handle c w Micro Switch Hand Torch 1 33 07301 20 Switch 1 14 75 34 C3055623 Handle Machine Torch 1 32 77 35 C3045012 Wrench for Electrode 1 6 23 36 C970 6mt Cable Assy Hand Torch 1...

Страница 15: ...or cutting operation 1 Do not touch the hot workpiece with bare hands to avoid burning 2 It is recommended not to ignite the arc in the air if not necessary for it will shorten the lifespan of the ele...

Страница 16: ...od ventilation This cutting machine can create powerful cutting current and has strict cooling requirements that cannot be met with natural ventilation Therefore the built in fan is very important in...

Страница 17: ...is on intake grills main voltage transformer inductance IGBT modules the fast recover diode and PCB etc Take care when blowing electronic components and do not dislodge any wiring connections Check th...

Страница 18: ...Parts List 8 Cut 60 80 16...

Страница 19: ...6932 Left plastic 26 10043995 EMC board 9 10049887 Base plate 27 10049741 rectifier bridge wires 10 10046933 Right plastic 28 10052876 Control board 11 10028470 Gas connector 29 10046896 Handle 12 100...

Страница 20: ...port 6 10004637 Quick connector 21 10043995 EMC board 7 10004622 Torch connector 22 10049050 Power transfer board 8 10006525 AC contactor 23 10049048 Arc starting control board 9 10035516 Reactor 24 1...

Страница 21: ...CUT 60 80 100 AIR PLASMA CUTTING MACHINE Order codes JP 60 JP 80 JP 100 Wilkinson Star Limited Issue 1 June 2015 Product is subject to change without notice xix...

Отзывы: