A WILKINSON STAR LIMITED PRODUCT 01-19 ISSUE 1
Category
Alarm method
Error
code
Welder
action
Causes
User measures
Overheated
Display error code,
accompanied by alarm
sound, warning
indicator light is on.
Err 1
Temporarily
turns off the
main circuit.
Main circuit
working
time is too
long.
Do not turn off, wait for a while
and continue to weld when the
overheating indicator goes out.
Phase loss
Display error code,
accompanied by alarm
sound, warning
Indicator light is on.
Err 2
Permanently
turns off the
main circuit;
need to
restart.
Input power
problem.
Check and repair input problem.
Under
voltage
Display error code,
accompanied by alarm
sound, warning
Indicator light is on.
Err 3
Temporarily
turns off the
main circuit.
Mains
supply low
(lower than
323VAC).
Please turn off the machine and
restart it. If the problem remains
have the mains supply checked by
a suitably qualified electrician.
Over
voltage
Display error code,
accompanied by alarm
sound, warning
Indicator light is on.
Err 4
Temporarily
turns off the
main circuit.
Mains
supply high
(higher than
437VAC).
Please turn off the machine and
restart it. If the problem remains
have the mains supply checked by
a suitably qualified electrician.
Control board
problem
Display error code,
accompanied by alarm
sound, warning
Indicator light is on.
Err 5
Permanently
turns off the
main circuit;
need to
restart.
Control
board
problem.
Contact the Jasic UK service
department.
Cooler problem
Display error code,
accompanied by alarm
sound, warning
Indicator light is on.
Err 6
Temporarily
turns off the
main circuit.
No water in
the tank or
tank isn’t
connected
properly.
Add water to the tank and check
if the tank is connected properly.
Secondary
inverter board
problem
Display error code,
accompanied by alarm
sound, warning
Indicator light is on.
Err 7
Permanently
turns off the
main circuit;
need to
restart.
Inverter
problem.
Contact the Jasic UK service
department.
Output
overvoltage
Display error code,
accompanied by alarm
sound, warning
Indicator light is on.
Err 8
Permanently
turns off the
main circuit;
need to
restart.
The output
cables are
too long.
Check whether the output cables
exceed 10m. If yes, shorten and
straighten the output cables to
avoid folding. If the welding lines
cross, arrange them in parallel.
Communication
problem
Display error code,
accompanied by alarm
sound, warning
Indicator light is on.
Err9
Permanently
turns off the
main circuit;
need to
restart.
Control
board and
display
board data
transfer
problem.
Contact the Jasic UK service
department.
9
ERROR CODES