A WILKINSON STAR LIMITED PRODUCT 01-19 ISSUE 1
outlet connection.
The gas inlet hose is connected at the rear of the
machine and the other end to a suitable
regulator / flowmeter attached to the gas supply
cylinder.
8
MAINTENANCE
ONLY SUITABLY QUALIFIED PERSONNEL SHOULD
CARRY OUT THESE CHECKS
WHEN REMOVING ANY COVERS SWITCH OFF AT
THE MAINS SUPPLY AND WAIT FOR 5 MINUTES
BEFORE REMOVING THE COVERS. COVERS
SHOULD ONLY BE REMOVED BY A SUITABLY
QUALIFIED PERSON
Check daily the condition of the machine, leads
and connections and repair or replace items when
necessary.
Keep hands, hair and tools away from the moving
parts such as the fan to avoid personal injury or
machine damage.
Clean the dust periodically with dry and clean
compressed air. In welding environments with
heavy fume and dust pollution, the machine
should be cleaned daily. The pressure of
compressed air should be at a low level in order to
avoid the small parts inside the machine being
damaged.
Avoid rain, water and vapour entering the
machine. If this occurs, dry the machine and check
the insulation of the equipment (including that
between the connections and that between the
connection and the enclosure). Only when there
are no abnormal phenomena anymore, can the
machine be used.
Check periodically whether the insulation cover of
all cables is in good condition. If there is any
deterioration they should be replaced.
When not in use the machine should be stored in a
clean dry place.