50
ALARM
CODE
ALARM ( description in
the cloud)
USER INFORMATIONS
91
HIGH GAS PRESSURE
High gas pressure.
Check the gas supply.
92
LOW GAS FLOW
Low gas flow.
Check the gas supply.
93
HIGH GAS FLOW
High gas flow.
Check the gas supply.
100
EXCEEDING INTERNAL
VOLTAGE LIMITS
Critical supply
voltage in the
main control
circuit.
1. Try to restart the machine. 2.
If the problem still exists then contact the
service center
101
CMOS BATTERY FAILURE
BACKUP VOLTAGE
FAILURE
1. Try to restart the machine. 2.
If the problem still exists then contact the
service center
102
HIGH CPU TEMPERATURE
The CPU
temperature is to
high (80°C)
1. Restart the machine then wait a few
moments until cool it down.
103
ERROR IN THE UID
CHIPSET
Communication
error in the
internal circuits.
1. Try to restart the machine. 2.
If the problem still exists then contact the
service center
104
ALARM 24V
The power supply
outside the limits
of 24V DC.
1. Try to restart the machine. 2.
If the problem still exists then contact the
service center
1. This issue came when there is overload in the
power supply or communication error with the
power inverter.
105
ALARM 5V
The power supply
outside the limits
of 5V DC.
1. Try to restart the machine. 2.
If the problem still exists then contact the
service center
1. This issue came when there is overload in the
power supply or communication error with the
power inverter.
106
ALARM -15V
The power supply
outside the limits
of -15V DC.
1. Try to restart the machine. 2.
If the problem still exists then contact the
service center
1. This issue came when there is overload in the
power supply or communication error with the
power inverter.
107
ALARM +15V
The power supply
outside the limits
of +15V DC.
1. Try to restart the machine. 2.
If the problem still exists then contact the
service center
1. This issue came when there is overload in the
power supply or communication error with the
power inverter.
110
INVERTER TEMPERATURE
ERROR
Error in the
inverter
temperature
sensor.
1. Try to restart the machine. 2.
If the problem still exists then contact the
service center
111
P&P TEMPERATURE
ERROR
Error in the P&P
temperature
sensor.
1. Try to restart the machine. 2.
If the problem still exists then contact the
service center
112
SHORT CIRCUIT IN THE
NTC 1 SENSOR
Short circuit in the
inverter
temperature
sensor.
1. Try to restart the machine. 2.
If the problem still exists then contact the
service center
113
SHORT CIRCUIT IN THE
NTC 2 SENSOR
Short circuit in the
P&P temperature
sensor.
1. Try to restart the machine. 2.
If the problem still exists then contact the
service center
120
MISMATCH PLUG&PLAY
MISMATCH PLUG
AND PLAY
check if TIGDC and TIG ACDC are installed
both
TIG ACDC and TIG DC are installed both.
wrong cabling of the control board
fault control board p&p
150
MISSING WATER
CIRCULATION
Insufficient water
in the cooler unit.
1. Insufficient water in the tank.
2. Fault in the water pump.
3. Refill the water tank.
151
LOW WATER
CIRCULATION
Low water flow in
the cooler unit.
1. Insufficient water in the tank.
2. Fault in the water pump.
3. Refill the water tank.
152
HIGH WATER
CIRCULATION
High water flow in
the cooler unit.
1. Fault in the water pump.
153
HIGH WATER
TEMPERATURE
High water
temperature
1. Fault in the water pump.
154
HIGH WATER PUMP
TEMPERATURE
Water pump
tempertaure is
high
1. Try to restart the machine. 2.
If the problem still exists then contact the
service center
171
WIRE FEEDER MOTOR
ENCODER ERROR
Missing feedback
from the motor
speed sensor.
1. Try to restart the machine. 2.
If the problem still exists then contact the
service center
172
WIRE FEEDER MOTOR
SPEED ERROR
The Wire Feeder
Motor speed is
out of the limits.
1. Blockage in the torch.
2. Check the wire exit point.
Содержание EVOLVE200 PLUS
Страница 1: ...EVOLVE200 PLUS USER MANUAL EVOLVE200 PLUS USER MANUAL REV 00...
Страница 12: ...EVOLVE200 PLUS USER MANUAL 10...
Страница 18: ...EVOLVE200 PLUS USER MANUAL 16...
Страница 33: ...EVOLVE200 PLUS USER MANUAL 31...
Страница 58: ...EVOLVE200 PLUS USER MANUAL 56 Appendix 2 MACHINE SCHEMATICS...
Страница 60: ...EVOLVE200 PLUS USER MANUAL 58 Ref 4 Ref 5 6 13 3 8 11 1 10 14...