![Jasic EVOLVE200 PLUS Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/jasic/evolve200-plus/evolve200-plus_user-manual_3447287023.webp)
EVOLVE200 PLUS USER MANUAL
21
2.6.4 MMA synergic mode setting
Press the PROG button to select the synergic material.
To select the MATERIAL, push the materials button
To select the ELECTODE SIZE, push the wire size button
and the diameter is show on the display.
Rotate KNOB 1 to select the diameter and confirm selection
by pressing KNOB 1 or by touch screen.
Rotate KNOB 1 to adjust the output current limitation for the
selected electrode. The range of this adjustment changes for
each type of electrode.
On the bottom side, the display will show the thickness of
the work part with selected current.
Stick synergic Materials and Electrode size
Material
Electrode size (mm)
RUTIL
2,0-2,5-3,25-4,0
SST
2,0-2,5-3,25-4,0
BASIC
2,5-3,25-4,0
CELL
2,5-3,25-4,0