background image

38

 

OPERATION 

-

 MMA

 

 

 Before starting any welding activity ensure that you have suitable eye protection and 

 

 protective clothing as, welding rays, spatter, smoke and high temperatures produced in the  

 

 process may cause injury to personnel. 

 

Also take the necessary steps to protect any persons within the welding area that may cause injury to.

 

 

MMA welding

 

Select MMA welding mode by selecting the MMA mode when in the 
home screen and this is acknowledged by going into the MMA screen 
and noting the MMA symbol is shown in the top left hand corner of the 
screen (circled red) in the image top right.

 

When in MMA mode you can select and adjust welding current as well 
as hot  start current and arc force parameters (which are displayed via 
the lower section of the screen in the image right) respectively as described below.

 

 

MMA Welding Current Adjustment

 

MMA welding current can now be adjusted via the central         
control adjustment dial and rotating this dial either clockwise          
or anticlockwise which will increase or decrease the welding                    
amperage shown on the screen (shown in image top right).

 

 

Please Note: 

Welding current can be adjusted out during welding. 

 

 
 

When in MMA mode, you can also adjust various MMA                     
parameters such as hot start and arc force and these can be       
adjusted via the parameter ‘P’ mode.

 

By pressing and then rotating the central control dial you can     
scroll to the parameter function to set back

-

end MMA parameter 

values.

 

 

Hot Start Current Adjustment

 

To select MMA hot start, rotate the central control dial until the hot start icon is highlighted green then 
press the central dial button, this will open the hot start adjustment display window. 

 

The hot start adjustment range is 0 ~ 60 amps and the factory setting is 30 amps. 

 

 

Arc Force Current Adjustment

 

To select MMA arc force, rotate the central control dial until the arc force icon is highlighted green then 
press the central dial button, this will open the arc force adjustment display window. 

 

The arc force adjustment range is 0 ~ 100 amps and the factory setting is 40 amps.  

 

 

VRD indicator 

 

By default the screen will display and show the MMA voltage (see image top right). In MMA mode, 
the VRD LED will be lit to indicate that VRD is active and the machine output voltage is under 12V.

 

 

 

PLEASE NOTE:

 

• 

The operator should set the parameters that meet the welding requirements. 

 

• 

If the selections are incorrect this may lead to problems such as an unstable arc, spatter or sticking    
of the welding electrode to the work piece.

 

• 

If the secondary cables (welding cable and earth cable) are long, select welding cable with a larger 
cross

-

section to reduce the voltage drop. 

 

 A

                                                            

B

 

Содержание EVO 2.0

Страница 1: ...1...

Страница 2: ...rect information should you require assistance or spare parts Date purchased ________________________________________ From where ________________________________________ Serial number ________________...

Страница 3: ...ronment 7 Protection from moving parts 7 Magnetic fields 7 Compressed gas cylinders and regulators 7 RF declaration 8 LF declaration 8 Materials and their disposal 9 Description of Symbols 10 Descript...

Страница 4: ...g should be regularly checked for damage and overheating Never use worn damaged under sized or poorly jointed cables Insulate yourself from work and earth using dry insulating mats or covers big enoug...

Страница 5: ...cutting is taking place Wear suitable protective flame resistant clothing gloves and footwear Ensure adequate extraction and ventilation is in place prior to welding and cutting to protect users and...

Страница 6: ...ding fume Ensure the welding zone is well ventilated and provision should be made for suitable local fume extraction system to be in place If ventilation is poor wear an approved airfed welding helmet...

Страница 7: ...ated by high currents may affect the operation of pacemakers or electronically controlled medical equipment Wearers of vital electronic equipment should consult their physician before beginning any ar...

Страница 8: ...permanent damage to your hearing Noise from cutting and welding equipment can damage hearing Always protect your ears from noise and wear approved and appropriate ear protection if noise levels are hi...

Страница 9: ...dangerous to the operator Do not dispose of the equipment with normal waste The European Directive 2012 19 EU on Waste Electrical and Electronic Equipment states that electrical equipment that has rea...

Страница 10: ...fective input current X Duty cycle The ratio of given duration time the full cycle time U0 No load voltage Open circuit voltage of secondary winding U2 Load voltage H Insulation class Do not dispose o...

Страница 11: ...carbon steel Self shielded welding of carbon steel 100 argon shielding of aluminum magnesium alloy Mixed gas welding 98 argon 2 CO2 of stainless steel Welding type selection welding base metal and gas...

Страница 12: ...CT 15 Home Button Pressing the home button will take you directly back to the home screen as shown in the display area image on page 13 16 The parameter control dial is also a control button which whe...

Страница 13: ...f the machine increases or decreases parameter values including welding current and when these parameters are adjusted the values are shown in the display screen Parameter adjustment knob A Parameter...

Страница 14: ...entral control dial to select the following option of MIG Synergic MIG Standard MMA Lift TIG Settings and User manual then press the central control dial button to select the required welding mode Tex...

Страница 15: ...or anti clockwise allows the user to navigate around the screen options adjust welding current or the various welding parameters that are available in all welding modes and user setting options 3 Hom...

Страница 16: ...settings When in any of the welding modes P function settings is a secondary menu where additional functions can be adjusted and set For example Material thickness wire size Pre post gas trigger mode...

Страница 17: ...t parameters as per example shown on page 15 for Synergic MIG from left to right parameters are set as follows Welding wire size 2T trigger mode welding inductance value pre gas time post gas time and...

Страница 18: ...een 0 2 seconds for MIG and 0 5 seconds for TIG Post Gas Time Post flow time icon indicates the gas post flow time which can be adjusted between 0 5 seconds for MIG and 0 10 seconds for TIG Material T...

Страница 19: ...re more parameters or options available but are located off screen continuing to rotate the central control dial will allow access to these additional parameter or options as noted in image B on page...

Страница 20: ...TIG mode the current can only be adjusted by the master encoder 2 Adjustment of other welding parameters Except for current and voltage all other parameters can only be adjusted in Parameter Settings...

Страница 21: ...ollowing steps If the user wants to adjust the operating mode in Synergic MIG rotate the central encoder to select and enter Parameter Settings P screen then rotate the encoder to select highlight and...

Страница 22: ...u to scroll through system icon options User Background Settings As per previous page to access and adjust user background settings from the home screen navigate to the background settings icon which...

Страница 23: ...n MIG and TIG mode if activated If the machine is not used within the preset period of time 5 minutes for example the machine will then enter a standby state where the unit powers down and the screen...

Страница 24: ...vely Remote Control Selection The EVO machine range of machines allow the user to use either wired or wireless technology for remote control purposes that offers the user to use wired or wireless hand...

Страница 25: ...ess device This is confirmed by the screen showing Pairing please wait Ensure that your remote device is in pairing mode see remote control instructions supplied with your device Once wireless pairing...

Страница 26: ...uired option of either Sure or Cancel as shown below 3 Once you have pressed the control dial on the highlighted green sure tab a new pop up green box will be displayed indicating Waiting for factory...

Страница 27: ...ct the language icon as shown right and press control dial button to access the language choice screen Rotating the control dial clockwise or anticlockwise will scroll you through the language choice...

Страница 28: ...ual screen you can rotate the control dial to select the section tabs on the left of the screen which are Operation Components Spare Parts Maintenance When you select for example select and enter the...

Страница 29: ...rror code is indicated along with the corresponding error description appears on the LCD display as the example right shows As long as an error code is shown welding operation is generally not possibl...

Страница 30: ...dial and for example pressing the Load option recall the saved welding parameters and load said program Pressing the back button will take you to the recalled welding screen where you can then commen...

Страница 31: ...s detailed below Work return lead to B and the torch trailing lead to A Ensure that a suitable shielding gas supply is connected Switch the power switch on the back panel to ON the machine is started...

Страница 32: ...mode icon is highlighted green then press the central dial button to select trigger mode This icon shown in the above screen image represents 2T torch trigger mode when this trigger option is selected...

Страница 33: ...select a saved welding job or save a welding job to and from the Memory function screen Once in the memory page you will note there are 4 memory slots to Select M1 M2 M3 and M4 and if a welding job w...

Страница 34: ...ttings Welding voltage is controlled and adjusted via the right control dial C When welding voltage is adjusted arc length also changes proportionally with it Rotating dial C clockwise will increase t...

Страница 35: ...ng rotate the central control dial until trigger mode icon is highlighted green then press the central dial button to select trigger mode This icon shown in the above screen image represents 2T torch...

Страница 36: ...you to the specific memory slot option page where you have three options of Save Load or Delete Selecting your desired option is carried out by rotating the control dial and for example pressing the...

Страница 37: ...t up the fan may start to rotate as the welding machine powers up and the control panel will also light up to indicate that the machine is ready to use as shown below PLEASE NOTE Caution when in MMA m...

Страница 38: ...ch as hot start and arc force and these can be adjusted via the parameter P mode By pressing and then rotating the central control dial you can scroll to the parameter function to set back end MMA par...

Страница 39: ...ckwise Insert the dinse plug on the work return cable into the socket on the front panel of the machine and rotate clockwise to tighten Attach the work clamp to the work piece Connect the supply gas h...

Страница 40: ...s Lift TIG pre gas selection and adjusting To select pre flow gas time setting rotate the central control dial until preflow is highlighted green then press the central dial button to adjust pre flow...

Страница 41: ..._________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________...

Страница 42: ...42...

Отзывы: