SAFETY INSTRUCTION

 

 

The working environment 

 

 

Ensure the machine is mounted in a safe and stable position allowing for cooling air circulation. 

 

Do not operate equipment in an environment outside the laid down operating parameters. 

 

The welding power source is not suitable for use in rain or snow. 

 

Always store the machine in a clean, dry space. 

 

Ensure the equipment is kept clean from dust build up. 

 

Always use the machine in an upright position. 

 

 

Protection from moving parts 

 

When the machine is in operation keep away from moving parts such as motors and fans. 

 

Moving parts, such as the fan, may cut fingers and hands and snag garments. 

 

Protections and coverings may be removed for maintenance and managed only by qualified  
personnel after first disconnecting the power supply cable. 

 

Replace the coverings and protections and close all doors when the intervention is finished and before 
starting the equipment. 

 

Take care to avoid getting fingers trapped when loading and feeding wire during set up and operation. 

 

When feeding wire be careful to avoid pointing it at other people or towards your body. 

 

Always ensure machine covers and protective devices are in operation. 

 

 

Risks due to magnetic fields 

 

The magnetic fields created by high currents may affect the operation of pacemakers or       
electronically controlled medical equipment. 

 

Wearers of vital electronic equipment should consult their physician before beginning any arc 
welding, cutting, gouging or spot welding operations. 

 

Do not go near welding equipment with any sensitive electronic equipment as the magnetic 

fields may cause damage. 

 

Keep the torch cable and work return cable as close to each other as possible throughout their length. 
This can help minimise your exposure to harmful magnetic fields. 

 

Do not wrap the cables around the body. 

 

 

Handling of compressed gas cylinders and regulators 

 

 

Mishandling gas cylinders can lead to rupture and the release of high pressure gas.

 

Always check the gas cylinder is the correct type for the welding to be carried out. 

 

Always store and use cylinders in an upright and secure position.

 

All cylinders and pressure regulators used in welding operations should be handled with care. 

 

Never allow the electrode, electrode holder or any other electrically 

hot

” 

parts to touch a    

cylinder. 

 

Keep your head and face away from the cylinder valve outlet when opening the cylinder valve. 

 

Always secure the cylinder safely and never move with regulator and hoses connected.

 

Use a suitable trolley for moving cylinders.

 

Regularly check all connections and joints for leaks. 

 

Full and empty cylinders should be stored separately.

 

 

Never deface or alter any cylinder 

 

 

 

 

Содержание EVO 2.0 LC-30

Страница 1: ...1...

Страница 2: ...ect information should you require assistance or spare parts Date purchased ________________________________________ From where ________________________________________ Serial number _________________...

Страница 3: ...ACDC operating manual Index Page Your New Product 2 Index 3 Safety Instruction 4 Package and Contents 9 Product Overview 9 Safety Precautions 9 Description of Symbols 10 Technical Specifications 10 G...

Страница 4: ...g should be regularly checked for damage and overheating Never use worn damaged under sized or poorly jointed cables Insulate yourself from work and earth using dry insulating mats or covers big enoug...

Страница 5: ...cutting is taking place Wear suitable protective flame resistant clothing gloves and footwear Ensure adequate extraction and ventilation is in place prior to welding and cutting to protect users and...

Страница 6: ...ding fume Ensure the welding zone is well ventilated and provision should be made for suitable local fume extraction system to be in place If ventilation is poor wear an approved airfed welding helmet...

Страница 7: ...ated by high currents may affect the operation of pacemakers or electronically controlled medical equipment Wearers of vital electronic equipment should consult their physician before beginning any ar...

Страница 8: ...permanent damage to your hearing Noise from cutting and welding equipment can damage hearing Always protect your ears from noise and wear approved and appropriate ear protection if noise levels are hi...

Страница 9: ...information please refer to the HSE website www hse gov uk PACKAGE CONTENTS AND UNPACKING Supplied within your new Jasic EVO product package will be the following items with each model Use care when...

Страница 10: ...CDC TIG range of machines Featuring low noise with stable coolant flow this product can meet the cooling requirements for our Jasic TIG welding equipment and TIG torches This product offers stable coo...

Страница 11: ...ined easily by un screwing and removing the front drain plug item No 7 in the above image Please ensure to add coolant cooling water when the input cable is disconnected from the power supply The two...

Страница 12: ...states the electrical equipment that has reached its end of life must be collected separately and returned to an environmentally compatible recycling facility In order to comply with WEEE regulations...

Страница 13: ...lt the ET 200P ACDC operating manual Symptoms Reason Troubleshooting Pump is not running The pump is only activated by the welding unit if welding current is flowing Check settings on the welding powe...

Страница 14: ...rrect or faulty mains supply Overloading during use Any modifications that are made to the product without the prior written consent Software errors due incorrect operation Any repairs that are carrie...

Страница 15: ..._________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________...

Страница 16: ...16...

Отзывы: