INSTALLATION
Installation
The owner/user are responsible for installing and using this welding machine according to this operating
manual.
Before installing this equipment, the owner/user shall
make an assessment of potential hazards in the
surrounding area.
Unpacking
Check the packaging for any signs of damage.
Contact your supplier in the first instance if any
item is missing or damaged. Carefully remove
the machine and retain the packaging or at
least until the installation is complete.
Lifting
The Jasic ET
-
200P ACDC does have an integrated handle for easy hand lifting only. Always ensure the
machine is lifted and transported safely and securely.
Location
The machine should be located in a suitable position and environment. Care should be taken to avoid
moisture, dust, steam, oil or corrosive gases. Place on a secure level surface and ensure that there is
adequate clearance around the machine to ensure natural airflow. Do not use the system in rain or snow.
Position the welding power supply near an appropriate power point ensuring you leave at least 30cm of
space around the machine to allow for proper ventilation.
Always place the machine on a firm level surface before using, ensuring it cannot tip over. Never use the
machine on its side.
Most metals including stainless steel can give off toxic fume when welded or cut.
To protect the operator and others working in the area its important to have adequate ventilation in the
work area to ensure air quality level meets all local and national standards.
Warning!
The following operation requires sufficient professional knowledge on electric aspects and
comprehensive safety knowledge. All connections shall be made with the power supply
turned off. Incorrect input voltage may damage the equipment.
Electric shock may cause death; after switching off the machine, there are still high voltages within
the machine, so if removing the covers do not touch any of the live parts on the equipment for at
least 10 minutes. Never connect the machine to the mains supply with the panels removed.
The electrical connection of this equipment shall be carried out by suitably qualified personnel
and these shall be made with the power supply off. Incorrect voltage may damage the equipment.
Input power connection
Before connecting the machine you should ensure that the correct supply is available.
Details of the machine requirements can be found on the data plate of the machine or in the technical
specification table shown on page 12 within this manual.
This equipment should always be connected by a qualified competent person.