background image

16

WARNING

Periodic check should be carried out by qualified professionals to ensure safety.
Thepower  of  the  switching  box  and  the  cutting  machine  should  be  shut  down
before periodic check to avoid personal injury accidents such as electric shock
and burns. Due to the discharge of capacitors, checking should be carried out
5 minutes after the machine is powered off.

4.2 Periodic check

Tips:

All maintenance and checking should be carry out after the power is
completely cut off. Make sure the power plug of the machine is pulled
out before uncovering the cutting machine.
When the machine is powered on, keep hands, hair and tools away from the
moving parts such as the fan to avoid personal injury or machine damage.

Avoid rain, water and vapor infiltrating the machine. If there is, dry it and check
the insulation of the cutting machine (including that between the connections
and that between the connection and the enclosure) with an ohmmeter. Only
when there are no abnormal phenomena anymore, can the machine be used.

Put the machine into the original packing in dry location if it is not to be used
for a long time.

Generally, periodic check should be carried out every 6 months, and it should
be carried out every 3 months if the cutting environment is dusty or with heavy
oily smoke.

Содержание CUT40 (L131)

Страница 1: ...MODEL CUT40 L131 CUT60 L204 CUT80 L205 INVERTER CUTTER OPERATOR S MANUAL CUT100 L201 CUT60 L211 L2040A SC A4 You Can buy this product at our E shop i prek galite sigyti m s el parduotuv je BUY NOW...

Страница 2: ......

Страница 3: ......

Страница 4: ...standard Relevant design plans and manufacturing technologies of this product are patented and international standards and meets GB15579 ICE60974 EN60974 This product is designed and manufactured acc...

Страница 5: ...als to avoid a fire Make ensure there are no inflammables near the cutting position to avoid a fire Beware of explosion Do not install the machine in an environment with explosive gas to avoid an expl...

Страница 6: ...tion to fire safety cutting Ensure there is fire extinguisher nearby and make sure someone has been trained to operate the fire extinguisher Do not weld closed container Do not use this machine for pi...

Страница 7: ...ics 5 2 INSTALLATION AND CONNECTION 6 2 1 Installation requirements 6 2 2 Precautions 7 3 OPERATION 9 3 1 Panel functions of L131 9 3 2 L211 10 3 3 Notes for cutting operation 12 3 6 Cutting parameter...

Страница 8: ...ls Single phase AC220V 50 60Hz Cooling mode Insulation grade Power factor Rated input capacity KVA Output current range A CUT XX XXXX CUT40 L131 6 4 40 96 60 230 20 40 0 2 0 4 15 2 10 1 0 20 60 315 20...

Страница 9: ...e and weight of the machine Figure 1 2 Appearance and size of the machine Unit mm Weight Kg Model Overall size L W H CUT40 L131 CUT60 L204 L211 415 155 315 540 250 380 568 259 446 9 17 26 5 CUT100 L20...

Страница 10: ...Quantity pcs Remark Material code Cutting torch Earth clamp Operator s manual CUT series Standard configuration Standard configuration Standard configuration Standard configuration 1 1 1 1 Cutting mac...

Страница 11: ...power supply inverter technology greatly reducing the volume and weight of the cutter and obviously enhancing the conversion efficiency by 30 Features of CUT series Economic and practical by adopting...

Страница 12: ...ork time of the machine under rated maximum current holding in the period when taking 10 minutes as a period The rated duty cycle of this machine is 40 60 Using the cutting machine continuously overru...

Страница 13: ...g torch Connect the copper nut on the cutting torch to the gas electric connector on the front panel of the machine and tighten it clockwise to avoid gas leakage Insert the quick plug on the work clam...

Страница 14: ...carry out cutting with the cutting machine placed on a platform with a pitch greater than 10 3 Installation and operation of the reducer valve Steps for reducer setting are as follows start the gas f...

Страница 15: ...is of automatic mains voltage compensation which ensures that the cutting current varies within the given range In case that the input mains voltage exceeds the tolerance value it would possibly damag...

Страница 16: ...display the cutting current Gas electric connector To connect the cutting torch Interface for torch trigger To connect the control signal of cutting torch Overcurrent indicator To indicate the machine...

Страница 17: ...8 Digital meter To display the cutting current Rocket switch For gas check cutting status conversion For 2T 4T cutting mode conversion Rocket switch output terminal To connect the earth clamp Overheat...

Страница 18: ...witch output terminal To connect the earth clamp Interface for torch trigger To connect the control signal of cutting torch Overcurrent indicator To indicate the machine is under overcurrent protectio...

Страница 19: ...initiate the cutting from the edge of workpiece unless penetration is needed Ensure spatters fly from the bottom of workpiece while cutting If spatters fly from the top of workpiece it indicates that...

Страница 20: ...ccording to the cutting parameters table workpiece material cutting thickness and cutting speed etc The figure in the below table is an approximation Table 3 1 Cutting speed in when cutting current is...

Страница 21: ...lame Difficult in arc ignition Irregular cut 0 25 0 5 0 5 0 5 25 20 15 5 0 1 0 3 0 3 0 3 3 3 2 9 3 3 2 0 7 0 7 10 1 1 0 95 1 1 0 6 30 35 40 0 1 0 1 0 1 0 1 0 1 0 38 0 65 0 65 0 65 0 15 0 1 Cutting thi...

Страница 22: ...ning Earth cable Cutting cable Whether the grounding wires including workpiece GND wire and cutting machine GND wire break off Whether the insulating layer of the cable is worn or the conductive part...

Страница 23: ...uncovering the cutting machine When the machine is powered on keep hands hair and tools away from the moving parts such as the fan to avoid personal injury or machine damage Avoid rain water and vapor...

Страница 24: ...he machine the power indicator illuminates and the fan works When pressing the control button of the cutting torch the solenoid valve inside the machine functions but there is no HF discharge rustling...

Страница 25: ...SHENZHEN JASIC TECHNOLOGY CO LTD No 3 Qinglan 1st Road Pingshan District Shenzhen Guangdong China www jasic com cn...

Отзывы: