Jasco P-1010 Скачать руководство пользователя страница 11

  

  

x

  

LIMITED WARRANTY 

 
Products sold by JASCO, unless otherwise specified, are warranted for a period of one year 
from the date of shipment to be free of defects in materials and workmanship. If any defects 
in  the  product  are  found  during  this  warranty  period,  JASCO  will  repair  or  replace  the 
defective part(s) or product free of charge. 
 
THIS  WARRANTY  DOES  NOT  APPLY  TO  DEFECTS  RESULTING  FROM  THE 
FOLLOWING: 
 
1) 

IMPROPER OR INADEQUATE INSTALLATION 

2) 

IMPROPER  OR  INADEQUATE  OPERATION,  MAINTENANCE,  ADJUSTMENT  OR 
CALIBRATION 

3) 

UNAUTHORIZED MODIFICATION OR MISUSE 

4) 

USE  OF  CONSUMABLE  PARTS  NOT  SUPPLIED  BY  AN  AUTHORIZED  JASCO 
DISTRIBUTOR 

5) 

CORROSION  DUE  TO  THE  USE  OF  IMPROPER  SOLVENTS,  SAMPLES,  OR  DUE 
TO SURROUNDING GASES 

6) 

ACCIDENTS BEYOND JASCO

í

S CONTROL, INCLUDING NATURAL DISASTERS 

 
This warranty does not cover the consumable parts listed below: 
 
1) 

Deuterium lamp, tungsten lamp, xenon lamp and other light sources 

2) 

Mirrors in the light source section, and cell windows 

3) 

Fuses, batteries, glassware, chart paper and ink 

 
The LC system only contains: 
4) 

Plunger  seals,  needle  seals,  cell  window  gaskets,  valve  seals,  disk  seals  and  other 
seal materials 

5) 

Tubing and fittings (e.g., ferrules, compression screws), and filters (e.g., inlet filters, line  
filters, other solvent filters) 

6) 

Pre-columns and guard columns 

 
THE WARRANTY FOR ALL PARTS SUPPLIED AND REPAIRS PROVIDED UNDER THIS 
WARRANTY  EXPIRES  ON  THE  WARRANTY  EXPIRATION  DATE  OF  THE  ORIGINAL 
PRODUCT. FOR INQUIRIES CONCERNING REPAIR SERVICE, CONTACT YOUR JASCO 
DISTRIBUTOR  AFTER  CONFIRMING  THE  MODEL  NAME  AND  SERIAL  NUMBER  OF 
YOUR INSTRUMENT. 
 
 

 

 

 

 

 

JASCO Corporation 

 

 

 

 

 

 

2967-5, Ishikawa-cho, Hachioji-shi 

 

 

 

 

 

 

Tokyo 192, JAPAN 

 

Содержание P-1010

Страница 1: ...P N 0302 0411A April 1999 P 1010 1020 1030 Polarimeter Hardware Function Manual Data Station Type...

Страница 2: ...the product is marked with this symbol refer to the instrument manuals to protect the instrument against damage WARNING A WARNING indicates an potentially hazardous situation which if not avoided coul...

Страница 3: ...ND CURRENT RATINGS Part No 0822 0102A 2 Warning for GROUND on Figure 1 2 or 3 WARNING MAINS PLUG GROUND PIN OR GROUND TERMINAL MUST BE CONNECTED TO GROUND Part No 0822 0104A Power On Off AC Input T3 1...

Страница 4: ...iRM PS AUX1 AUX2 LC Out Temp Control Analog Out Se ri a l GND GND 1 2 Figure 2 Rear panel of P 1020 iRM PS AUX1 AUX2 LC Out Temp Control Analog Out FUSE T 10A 100 120V T 5A 200 240V AC Input Power On...

Страница 5: ...sample exceeds 50 the correct optical rotation may not be shown if the sample with the large optical rotation is placed in the sample chamber first In this case use the following procedure 1 Beforeha...

Страница 6: ...nown sample 4 After measuring the unknown sample open the sample chamber lid replace the unknown sample with the known sample used above close the lid and measure until the optical rotation stabilizes...

Страница 7: ...gnetic compatibility Generic immunity standard Part 1 Residential commercial and light industry IEC1000 4 2 Electromagnetic compatibility for industrial process measurement and control equipment Part...

Страница 8: ...r experienced users Before using the instrument please read this instruction manual carefully and make sure you fully understand its contents This manual should be easily accessible to the operator at...

Страница 9: ...nder atmospheric pressure of 750 1060hPa 6 Avoid strong magnetic fields and sources of high frequency The instrument may not function properly when near a strong magnetic field or high frequency sourc...

Страница 10: ...ON THE USE OF JASCO SOFTWARE COPYING SOFTWARE FOR PURPOSES OTHER THAN BACKUP TRANSFER OR LICENSING OF THE RIGHT TO USE SOFTWARE TO A THIRD PARTY DISCLOSURE OF CONFIDENTIAL INFORMATION REGARDING SOFTWA...

Страница 11: ...DENTS BEYOND JASCO S CONTROL INCLUDING NATURAL DISASTERS This warranty does not cover the consumable parts listed below 1 Deuterium lamp tungsten lamp xenon lamp and other light sources 2 Mirrors in t...

Страница 12: ...2 Names and Functions of Each Part 5 2 1 Overview 5 2 2 Rear panel 5 2 3 Filter 8 3 Maintenance 9 3 1 Cautions in Use 9 3 2 Cleaning Sample Chamber 9 3 2 1 Dismounting the sample cell unit 9 3 2 2 Cle...

Страница 13: ...nter Equipped with Centronics parallel interface Display Liquid crystal panel Language Japanese English Temperature measurement Within cell holder cell sample Temperature measurement range 0 40 C Mini...

Страница 14: ...ity Data processing Edit data Statistical calculation average value standard deviation coefficient of variation Other functions Recognizes light source filter External terminal External start External...

Страница 15: ...100 115 200 220 and 240 VAC 10 50 60 Hz 530 W 1 3 Hardware Structure Figure 1 1 shows a block diagram of the polarimeter Light from the light source lamp passes through slit S lens L and filter F bef...

Страница 16: ...AMP Generator Ref AM P H T AMP Main AMP Servo AMP Accessory Micro Computer Servo Motor G PC RS 232C SO Light source S Slit L Lens F Filter P Polarizer M Modulator A Analyzer PM Photomultiplier tube G...

Страница 17: ...mp The lamp is housed here Contains a filter for changing over wavelength Includes the cell holder light beam aperture changer and sensor for temperature measurement The aperture changer can be set at...

Страница 18: ...X1 AUX2 LC Out Temp Control Analog Out GND GND 1 2 3 4 5 7 8 9 10 11 6 Figure 2 3 P 1020 rear panel P 1030 rear panel iRM PS FUSE T10A 100 120V T5A 200 240V AC Input Power On Off 50Hz 60Hz Hg Na Seria...

Страница 19: ...specified fuse for the voltage is contained here Be sure to match the voltage of the power source being used Enables power to be supplied to the intelligent remote module iRM Connector for connecting...

Страница 20: ...ing the left and right ends of the disk pops up the lid of the filter unit The filter must be inserted in a specified direction Insert it by noting the wavelength indication at the top of the filter a...

Страница 21: ...a day s measurement turn OFF the Power switch wait for about 15 minutes for the lamp to cool down and then put on the dust cover 3 2 Cleaning Sample Chamber If sample is spilt in the sample chamber wi...

Страница 22: ...etely with gauze wetted with ethyl alcohol and then allow the sample chamber to dry up 3 2 3 Remounting the sample cell unit 1 Install the sample cell unit 1 Fit the positioning pins in the sample cha...

Страница 23: ...5330 0080 5330 0006 5330 0099 5332 0001 1009 0042A 1009 0043A 1009 0044A 1009 0045A 1009 0059A Sodium lamp Mercury lamp Halogen lamp The glow discharge tube Filter 589nm Filter 578nm Filter 546nm Fil...

Страница 24: ...ut 30 minutes 2 Set data mode to optical rotation alpha 3 Set the parameters as follows Lamp WI or Na Wavelength filter 589 nm Integration 5 sec Sample chamber aperture 8 mm Auto meas On Auto print On...

Страница 25: ...ees Degrees Degrees Li 6708 Cd 6438 50 51 55 04 50 50 55 05 0 01 0 01 Fe 4384 Fe 4376 126 5 127 2 126 7 127 2 0 12 Zn 6362 56 51 56 45 0 06 Hg 4358 128 49 128 3 0 12 Na 5893 Cu 5782 Hg 5780 Cu 5700 Hg...

Страница 26: ...amp into the socket 5 Mount the lid into place 6 Turn the Power switch On and make sure that the instrument operates properly See 3 4 Performance Check for details 3 5 2 Replacing Lamp for P 1020 Repl...

Страница 27: ...lamp 2 Take out the Hg lamp from its case and insert it perpendicularly into the socket by aligning the prongs of the lamp with the socket holes 3 Set the lamp selector switch on the rear of the lamp...

Страница 28: ...ce the glow discharge tube in the lamp housing Use commercially available glow discharge tube FG 4P 200 volts WARNING The lamp is still very hot after turning the Power switch Off Therefore wait at le...

Страница 29: ...ed type and current rating 1 Turn the power switch off and unplug the power cable from the socket 2 Insert a standard driver into the fuse holder on the rear panel Figure 3 4 Then press and turn about...

Отзывы: