The User Manual of JAC200 Series General Frequency Converter
- 81 -
electrical machine.
6. Simple PLC
The given output voltage should be determined through setting Group FA parameter if the voltage sourse is
simple PLC.
7. PID
The output voltage is produced on the basis of PID closed loop. Please refer to the introduction of PID in
Group FA for details.
8. Communication reference
The communication reference means that voltage is set by upper computer through communication mode.
The usage mode of VF separation voltage source is similar to that of frequency source. See the introduction
of the selection of F0-03 main frequency source. Where, various selections correspond to the given 100.0%
which is the rated voltage of motor (the corresponding set value is absolute value).
F3-15
Voltage acceleration time of
the VF separation
Default value
0.0s
Set range
0.0s
~
1000.0s
F3-16
Voltage deceleration time of
the VF separation
Default value
0.0s
Set range
0.0s
~
1000.0s
Voltage acceleration time of the VF separation refers to the time which the output voltage accelerates from
0 to the rated voltage of motor. See the t1 in the figure.
Voltage deceleration time of the VF separation refers to the time which the output voltage accelerates from
rated voltage of motor to 0. See the t2 in the figure.
Fig. 6-5 Separation diagram
Group F4 Input terminal