Operating Instructions T411 / T412
JAQUET AG
Revision: 003
17/27
8.4 Parameter list and ranges
If you already have a configuration file you can open and view it using the T400 Windows Software menu
File
Open
You can also connect the T400 to a PC (see section 8.2) and read back the parameters,
T400
Read parameters
Once loaded into the software the parameter set may be printed via
File
Normal Windows file handling rules apply.
Parameter list and ranges. Factory settings are shown in bold.
Instrument Type
Manufacturer’s code
Software version
Calibration date
Configuration < System >
Machine factor
1.0000E-07 ...
1.0000
... 9.9999E+07
Minimum Measuring time
2
/ 5
/ 10 / 20 / 50/ 100 / 200 / 500
ms
/ 1/ 2 / 5 Seconds
Min displayed measured value
1.0000E-12 ...
1
... 1.0000E+12
Alarm definition
Only System error /
System error OR Sensor Monitoring
Configuration < Sensor >
Sensor Type
Active / Passive
Sensor input
Analog (Sign)
/ Digital (IQ)
Sensor current minimum
0.5 ...
1.5
... 25.0mA
Sensor current maximum
0.5 ...
25.0
mA
Configuration < Analog output >
Measuring range start value
0.0000
... 90% of the end value
Measuring range end value
1Hz …
2000.0
…
500000
Output range
0 ... 20mA
/ 4 ... 20mA
(T411)
0 ... 10V / 2 ... 10V.
(T412)
Time constant (Damping)
0.0
... 9.9s
Configuration < Limits >
Status
Limit 1
On
/ Off
Status
Limit 2
On
/ Off
Mode
Limit 1
Normal
/ Inverse
Mode
Limit 2
Normal
/ Inverse
Lower Set point
Limit 1
0.1 …
200.00
… 500000
Upper Set point
Limit 1
0.1 …
300.00
… 500000
Lower Set point
Limit 2
0.1 …
400.00
… 500000
Upper Set point
Limit 2
0.1 …
500.00
… 500000
Configuration < Relay control >
Switching of control A/B
Selection of actuator
None (always control A) /
Binary Input B1
Delay time
0
... 2’000 s
Relay Assignment
Control
A
Alarm / Sensor monitor /
Limit
1 / Limit 2 / Window / On / Off
Acknowledge A
Without acknowledge (no hold function)
/
Relay held when control active /
Relay held when control inactive
Acknowledge B
Alarm / Sensor monitor / Limit 1 /
Limit 2
/ Window / On / Off
Acknowledge B
Without acknowledge (no hold function)
/
Relay held when control active /
Relay held when control inactive