20
9 Vcc
6 Vcc
8 CTS
5 CTS
7 RTS
4 RTS
2 RxD
3 RxD
3 TxD
2 TxD
5 GND
1 GND
Application case
1.
G356-----DOS/V scanner
It can be connected directly.
2.
G356-----Panasonic scanner (ZE84RMD4JK)
Case1: Please exchange the inner cable WI-908 with WI-906.
WI-908+SCANNER
Case2: please use the interface cable WI-1370.
WI-906+WI-1370
3.
G356-----DOS/V PC
It can be connected directly by the cross cable.
4.
G356-----GP965
Case 1: Please exchange the inner cable WI-907 with WI-837N
WI-837N+
GP965
Case2 : please use the interface cable WI-1369.
WI-906+WI-1369 (SCOM1)
or WI-907+WI-1369 (SCOM2)
6 Appendix
Number of PLU & PB actually maximum occupation
PLU 12 char.
9269
PLU 20 char.
7657
PLU 15 char.
7657
PB 7657
Paper near end level
Point
Paper yes
No paper
J15-8 4.71 0.320
JNEND 9.3mV 5.02
J15-4 4.13 180.9mV
RNEND 10.7mV 5.02
HARD RESET
procedure
(1)
remove the cabinet
(2)
DIP SW1 ON
(3)
Power ON
(4)
Short the JP1 on the CPU board.
(5)
After few second display will light.
(6)
If “E006” appear on the display, off the power and execute the “ALL CLEAR”.