4 Configuration continued
At this point the user has 10 seconds to enter one of the following commands followed by a line termination (‘Enter’
key on PC’s):
TERMINAL MENU COMMANDS
COMMAND
FUNCTION
?, H
Outputs the current menu options.
Q, QUIT
Exits the menu and causes the POTSwap to proceed with the normal operation.
DEBUG xx
Factory use only
DUMP Adr Len
Factory use only
XMODEM
Download upgrade binary
REBOOT
Restart Application
CONFIG
Configure Settings
PROVISION
IDENTIFY
Display Cellular MEID (Mobile Equipment IDentifier) and phone number
These commands are NOT case sensitive. Terminal menu commands operate as follows:
?, H: Entering a ‘?’ or ‘H’ character will output the Terminal menu command menu again. It can be useful if the
menu has scrolled off of a screen.
Q ,QUIT: Entering ‘Q’ or ‘QUIT’ will exit the DEBUG menu and continue with the normal start-up and operation of
the POTSwap.
DEBUG xx: DO NOT USE - Factory use only.
DUMP Adr Len: DO NOT USE - Factory use only.
XMODEM: Used for firmware upgrades.
REBOOT: Entering ‘REBOOT’ will restart the POTSwap, similar to pressing the RESET button.
CONFIG: Entering ’CONFIG’ will cause the configuration menu to be output:
Janus Remote Communications - WireLine II Board - POTSwap Configuration
=======================================================================
Microphone Level
[25] 0-31
Speaker Level
[25] 0-31
Echo Cancellation
[1] 0-1
Open Switching Interval [900 ] 0-1200 ms
Dialing Tone Timeout
[30000] 500-60000 ms
Dialing Digit Timeout [4000 ] 250-15000 ms
Busy Dwell Timeout [6000 ] 1000-30000 ms
Fixed Format Dialing
[0] 0-1
Fail Over Mode
[0] 0-2
SLIC ADC Gain
[2] 0-8
SLIC DAC Gain
[4] 0-8
Loop Current Limit
[2] 0-7
Loop Closure Sense Type [0] 0-1
Loop Closure Threshold [8 ] 0-63
Press M=Modify, D=Defaults, X=Exit and Save, Q=Quit and Discard
The configuration menu lists the name of the parameter, the current setting (in brackets), and the range or values of
settings available. These settings may vary depending on the model of Plug-In Terminus terminal used in the POTSwap.
Following the list of parameters are options for changing the configuration settings or leaving this menu: M, D, X, and
Q. These single character command options can be entered in upper or lower case, and no enter key is required.