background image

Terminus T3 User Guide JA19-UM

    

 Page 6    Rev: 00    Date: 05/25/17

  © Copyright 2017 Janus Remote Communications   

Specifications subject to change without notice

   All Rights Reserved   See website for latest revision.    Not intended for life support applications.

Electrical Specifications:

Absolute Maximum Ratings:

Parameter 

 

Minimum 

Nominal 

Maximum 

Unit 

Note

Storage Temperature 

 

-40 

85 

°C 

1

Supply (Supply & Enable Input) 

 

Volt 

1,2

VIN (RS-232 Inputs) 

 

-25 

25 

Volt 

1

Notes:
1)  Operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions is not implied.  

Exposure to Absolute Maximum Rating conditions for extended periods of time may affect device reliability.

2)  The supply inputs are protected from transients beyond the Recommended Operating Conditions.  

If transients persist the supply will be latched in a disable state until the input is lowered.

Recommended Operating Conditions:

Parameter 

 

Minimum 

Nominal 

Maximum 

Unit 

Note

Operational Temperature: 

 

-40 

25 

85 

°C 

Supply  

 

4.75 

5.0 

5.25 

Volt 

Peak Supply Current 

 

2.0 

Amp 

1

Note:

1)  Peak Supply Current specification is stated as the minimum amount of current the external power supply must be able to supply during the TX burst 

of the embedded cellular radio. Please refer to the Plug-In User Manual for power supply characteristics of the embedded Plug-In Module in the 
Terminus T3. Plug-In User Manual can be downloaded at http://www.janus-rc.com/terminuscf.html

Typical Operating Conditions - HSPA910T3:

Mode   

 

 

Type 

Average (mA)

1, 2

 

Description

Terminal Disabled 

 

0.14 

 External Disable Grounded, modem off.

Using: RS-232

AT+CFUN=1 

 

 

WCDMA 

34 

Idle, no call in progress. Full functionality of 

     

 

 

 

GSM 

the module

AT+CFUN=4 

 

 

WCDMA 

33 

Disabled TX and RX; module is not registered 

     

 

 

 

GSM 

on the network

AT+CFUN=5 

 

 

WCDMA 

10 

 Full functionality with power saving; Module registered 

     

 

 

 

GSM 

on the network can receive incoming calls and SMS

AT+CFUN=0 

 

 

WCDMA 

10 

 Minimum functionality. In this mode the AT interface  

     

 

 

 

GSM 

is not accessible. Must be woken up externally by 

     

 

 

 

 

 

SMS or Socket attempt.

Using: USB

AT+CFUN=1 

 

 

WCDMA 

38 

Idle, no call in progress.  

     

 

 

 

GSM 

Full functionality of the module.

AT+CFUN=4 

 

 

WCDMA 

37 

Disabled TX and RX; module is not registered on the 

     

 

 

 

GSM 

network

AT+CFUN=0 

 

 

WCDMA 

Full functionality with power saving; Module registered 

     

 

 

 

GSM- 

 

on the network can receive incoming calls and SMS

Using: RS-232 & USB

AT+CFUN=1 

 

 

WCDMA 

51 

 Idle, no call in progress. Full functionality of 

     

 

 

 

GSM 

the module.

AT+CFUN=4 

 

 

WCDMA 

51 

 Disabled TX and RX; module is not registered on the 

     

 

 

 

GSM 

network

AT+CFUN=5 

 

 

WCDMA 

11 

Full functionality with power saving; Module registered 

     

 

 

 

GSM 

on the network can receive incoming calls and SMS

AT+CFUN=0 

 

 

WCDMA 

10 

Minimum functionality. In this mode the AT interface 

     

 

 

 

GSM 

is not accessible. Must be woken up externally by 

     

 

 

 

 

 

SMS or Socket attempt.

Note:

1)  Average Supply Current specification is stated as the maximum average current the Terminus T3 terminal can draw while maintaining junction 

temperatures within the internal power supply IC’s specifications. It is the applications responsibility to maintain operation within this limit to maintain 
reliable operation over the life of this terminal product.

2)  Values taken with GPS turned OFF. When GPS is used, expect a 20mA increase during operating states. 

Содержание Terminus T3

Страница 1: ...Terminus T3 Products User Manual Bulletin JA19 UM Revision 00 Date 25 May 2017 ...

Страница 2: ... disclosure to persons other than the officers employees agents or subcontractors of the owner or licensee of this document without the prior written consent of Connor Winfield is strictly prohibited Connor Winfield makes every effort to ensure the quality of the information it makes available Notwithstanding the foregoing Connor Winfield does not make any warranty as to the information contained ...

Страница 3: ...terfaces and an easy to use input to control ON OFF remotely Additionally Janus offers Python examples for the modems equipped with the interpreter to add scripting capabilities to your application Figure 1 T3 Terminal Block Diagram T3 Connections Terminals The 4 position terminal section serves as the power supply input It is also the access point for the external disable input Janus carries mati...

Страница 4: ...ust come from the main terminal input LED Indicators The T3 contains two LEDs for feedback to the user Status Green LED This LED is T3 feedback on readiness of the modem to accept commands and is automatically controlled internally When the unit is available for communications this will be illuminated When the modem is not ready either through external disable control or the use of low power AT CF...

Страница 5: ...d Ground SIM Card HSPA910T3 and LTE910T3 Models require a SIM card The SIM card port is located inside of the T3 on the module itself To insert a SIM card please follow these instructions Step 1 To access the SIM card holder remove the four TX 10 screws from the ruggedized aluminum enclosure These screws are located on the panel of the T3 that includes the RS232 DB9 and RF connections Step 2 Slide...

Страница 6: ...l Disabled 0 14 External Disable Grounded modem off Using RS 232 AT CFUN 1 WCDMA 34 Idle no call in progress Full functionality of GSM the module AT CFUN 4 WCDMA 33 Disabled TX and RX module is not registered GSM on the network AT CFUN 5 WCDMA 10 Full functionality with power saving Module registered GSM on the network can receive incoming calls and SMS AT CFUN 0 WCDMA 10 Minimum functionality In ...

Страница 7: ... in WCDMA1700 140 MHz in WCDMA1900 250 MHz in WCDMA2100 Gain Gain 3dBi Impedance 50W Input Power 33 dBm 2W peak power in GSM 24 dBm Average power in WCDMA VSWR Absolute Max 5 1 VSWR Recommended 5 1 EVDO910T3 Frequency Range Depending on frequency bands provided by the network operator the customer should use the most suitable antenna for those frequencies Bandwidth 70MHz in CDMA BC0 140 MHz in CDM...

Страница 8: ...LTE 1900 B2 140Mhz LTE 1700 B4 445Mhz LTE 850 B5 70Mhz LTE 700 B17 42Mhz Gain Gain 3dBi Impedance 50Ω Input Power 33 dBm 2W peak power in GSM 24 dBm Average power in WCDMA LTE VSWR Absolute Max 10 1 VSWR Recommended 2 1 LTE910T3 Verizon Frequency Range Depending on frequency bands provided by the network operator the customer should use the most suitable antenna for those frequencies Bandwidth LTE...

Страница 9: ...Communications Specifications subject to change without notice All Rights Reserved See website for latest revision Not intended for life support applications Mechanical Specifications 1 811 0 790 4 1142 2 3500 2250 4491 5 2142 1 0625 3250 All measurements in inches unless otherwise noted ...

Страница 10: ... 1 Attach the cellular antenna to the SMA bulkhead connector If applicable insert the SIM card to the modem s SIM holder Connect the RS232 cable or USB cable to the DB9 or USB connection respectively Step 2 Apply power to the T3 via the terminal blocks The T3 will begin booting the modem and you will see the amber LED illuminate In a few moments the green LED should illuminate indicating the modem...

Страница 11: ...xtra steps that are thoroughly detailed in our Provisioning App Note found here http www janus rc com Documentation JA01 AN111_Provisioning CDMA pdf Step 6 Check the network status by entering AT CREG without the quotations and press ENTER The response will be CREG 0 1 or CREG 0 5 meaning the device is registered to the home network or roaming respectively If the response is different than this pl...

Страница 12: ...NECT This opens a remote connection via socket IPP the remote host port of the server you are trying to connect to 0 to 65535 IPA the IP address of the server you are trying to connect to in the format xxx xxx xxx xxx At this point a data session is active and data can be sent from the Terminus to the remote device and visa versa To exit the data session and return to command mode send the charact...

Страница 13: ...ntinued EVDO910T3 The data can be acquired in two methods Method 1 Send command AT GPSP 1 cr Send command AT GPSACP cr GPSACP can retrieve GPS data at any point when GPSP 1 Method 2 Configure Unsolicited NMEA Data Send command to enable NMEA stream AT GPSNMUN enable gga gll gsa gsv rmc vtg cr Select parameter 3 to enable or 0 to disable for your NMEA stream requirements EXAMPLE AT GPSNMUN 3 1 1 1 ...

Страница 14: ...or Winfield Corporation 2359 Diehl Road Aurora IL 60502 630 499 2121 info janus rc com www janus rc com Terminus T3 Products User Manual Terminus Models Ordering Ordering Description HSPA910T3 v1 00 HSPA UMTS EDGE GPRS GSM AT T Certified EVDO910T3 v3 00 EV DO Verizon CDMA910T3 v2 00 CDMA 1xRTT Sprint CDMA910T3 v3 00 CDMA 1xRTT Verizon CDMA910T3 v4 00 CDMA 1xRTT Aeris LTE910T3 v1 00 LTE AT T LTE910...

Отзывы: