background image

to 160-250°C (set the temperature according to the material and thickness of the foil/film, 
the  thicker  the  foil/film,  the  higher  the  temperature  is).  The  average  temperature  is 
180°C . 
The sealing time can be adjusted in PLC, adjust the time according to the sealing effect. 

The filling volume can be adjusted by the valve. 
When operating the machine, check the working condition such as running of the spare 
parts,  the  fixing  of  the  screws,  air  pipe  connection.  If  anything  wrong,  stop  the  machine 
immediately and fix it, then restart the machine. 
When the temperature reaches the setting temperature, put the cups into the cup mould, 
install the  film on the film set or  put the  foils in  the foil setting system, turn the rotary 
board,  the  indicating  light  is  on,  the  machine  is  on  automatically  filling  and  sealing,  the 
finished products should be taken out manually. 

IV. Installation and Adjustment 

1.

 

After opening the package, check the spare parts first to make sure you get all the parts. 
Check the screws tight or loose, check the operation of the parts. 

2.

 

Adjust the temperature according to the thickness of the film/aluminum foil. Adjust 
the  volume  by  the  cylinder  valve.  The  temperature  time  and  sealing  time  can  be 
adjustable. 

V. Maintaining 

1.

 

Check  the  air  source pressure before  running, the  average  air pressure  should be 0.6-
0.7Mpa.  To  insure  the  good  working  of  the  cylinder,  drain  the  waste  water  in  thefilter 
regularly. 

2.

 

After working, let the heating part  cool on  room temperature. Clean the  filling tank 
with hot water and drain the water. Clean the aluminum board to prevent corrosion and 
aging. 

3.

 

Clean the heating part to better the sealing effect. 

4.

 

Connect the machine earth wire properly to safe using. 

5.

 

Set the sealing temperature from low to high to insure the sealing temperature more 
even and better sealing effect. 

6.

 

Stop the machine immediately when breakdown happens, the whole machine is on reset 
condition,  shut  down  the  power  and  check  the  breakdowns.  After  fixing,  restart  the 
machine. 