29
Mechanical adjustment
Needle plate replacing bar
1. While pressing the needle up/down and lock stitch
buttons, turn the power switch on.
The LCD display “----”.
Press “5” key to enter the sensor test mode.
Needle plate
attached:
Needle plate for
straight stitch
attached:
2. Be sure that S symbol appears and blinks when the
needle plate is attached.
3. Replace the needle plate with the needle plate for
straight stitch. Be sure that S symbol and number 3
appears.
If not, adjust the micro switch base plate position (see
page 33).
* To remove the needle plate, press the needle plate
replacing bar in the direction of arrow with a
screwdriver.
To check:
S symbol blinks
S symbol appears
3 appears
1
2
Содержание Skyline S5