20
TO CHANGE THE RECEPTACLE (MACHINE SOCKET UNIT)
TO REMOVE
1.
Remove the belt cover (see page 4).
2.
Cut the cord binder.
3.
Pull out the connectors from board A unit and board “C” case unit.
4.
Remove two set screws and change the receptacle (machine socket unit).
TO ATTACH
5.
Follow the above procedure in reverse.