TO ADJUST THE NEEDLE BAR HEIGHT
Correct Setting:
The distance between the tip of needle on the right and the surface of needle plate should be 11.2 to 11.6
mm when the needle bar is at the highest position.
To adjust:
1. Remove the face plate unit.
2. Turn the balance wheel toward you with your hand, and set the needle bar at the highest position.
3. Loosen the setscrew A to adjust the height, and tighten, the setscrew A after the adjustment is done.
4. Turn the balance wheel toward you one cycle, and recheck the needle bar height.
5. Attach the face plate unit.
Setscrew A
Needle bar
Needle No. 14
11.2 to 11.6 mm
Surface of needle plate