Installation Instructions Janfire Pellet Boiler Integral Typ 25
IA 32580002 EN_Ver5
Janfire 2014
6(25
)
2
Technical Data
Janfire Pellet Boiler
Power
230 V AC ± 10 %, 50 Hz
Load
3 VA
Measurement accuracy of water
temperature sensor
0– 100°C ± 1°C
Min Return Water temperature
55 ° C
Output
23 kW
Boiler class according to EN 303-5 4.4.2
Class 5
Relay output
5 A 250 V AC
Fuse
5A T
Water tank volume
180 litres
Water resistance 10K/20K
25,3/14,1 mbar
Max operating pressure
3 bar
Water resistance at 10 K difference
between flow and return line
25,3 mbar
Water resistance at 20 K difference
between flow and return line
14,1 mbar
Ash/fire box
100 litres
Weight
280 kg
Boiler type
Nor condensing, negative pressure controlled
Hot water
High efficiency heat exchange coil C22 mm
L=11m OBS Option
Flue connection
Backwards Ø 150 mm
Convection part
Vertical tubes
Operation thermostat
Adjustable intervals up to 15 °C
Flue gas thermometer
Option
Sweeping handle
Automatic controlled
Shunt
Option Mounted on Hot Water Flange
Control panel
With buttons
Safety cut-out
Mounted on the top of the door
Required Draft in furnace
-10 pascal
Exhaust Temperature Nominal/min load
145/73° C
Combustion period
Cleaning manual after use of 6 ton pellets
Fuel
Wood pellets EN 14961-2 Class A1 Ø 6-12 mm
Noise emission
61 db