Filter to Heater
Connector
Pump to Filter
Connector
A.
B.
Heater to Chlorinator
Connector
C.
A.
B.
C.
C. CS Standard (VPK-CSSTD)
Figure 6. CS Standard Equipment Pad
Figure 4. Diverter Valve Position (Solar Disabled)
Figure 5. Diverter Valve Position (Solar Enabled)
Figure 3. Connections from Versa Plumb
®
piping to
the Solar Connector
From Solar
Collector Cells
Check Valve
To Heater
From Filter
Diverter Position
(Solar Disabled)
To Solar
Collector Cells
From Solar
Collector Cells
Check Valve
To Heater
From Filter
Diverter Position
(Solar Enabled)
To Solar
Collector Cells
From Solar
Collector Cells
Check Valve*
Heater
Filter
3 Port Diverter Valve with
Actuator Controlled by
Solar Controller*
*Check Valve and Jandy Valve Actuator not included in kit.
To Solar
Collector Cells
1. Position the pool suction and return lines in front of
the equipment pad location.
2. Position the various equipment pad components.
Bring the suction and return piping up through the
perforated holes on the template.
3. Connect the pump to the suction lines (pool only or
pool/spa combo) using CPVC cement and primer.
The length of pipe into the suction port of the pump
should be a minimum of four (4) times the pipe
diameter.
4. Use CPVC cement and primer and connect the
pump to the filter using the sweep elbow with the
½” NPT plug component of the kit, marked as “A”
in figure 6. This positions the filter.
5. Use CPVC cement and primer
and connect the filter
to the heat pump using the flange tail piece with
union nut, marked as “B” in Figure 6. Use CPVC
cement and primer
and glue the flange tail piece
directly into the standard tail piece on the heat pump
inlet port. This positions the heat pump.
6. Attach the check valve (marked as “C” in figure 6)
to the outlet of the heat pump making sure the flow
arrow points in the correct direction.
7. If desired, attach the salt chlorinator spool or a
blank spool assembly provided in this kit to the
check valve and then run the return line from the
spool to the trench using CPVC cement and primer.
NOTE
Also included in the Versa Plumb Kit are two (2)
additional 3-way valves and a spare 12” of pipe
for your use in the event that you add additional
components on the return system.
3. Install the solar controller (not shown) per the
manufacturer’s instructions and connect to the
Jandy valve actuator on the Jandy 3-port diverter
valve. The Jandy valve actuator must be adjusted
to provide the diverter positions shown in Figures 4
and 5 in conjunction with the solar controller.
Page 4
Jandy
®
Pro Series Versa Plumb
®
Kits
|
Replacement Kit Instructions
Page 4